Experimental steam turbine with five high pressure stages results is described. The great effort is paid to the steam parameters over the individual stages during gradual start-up to nominal operating parameters. Especially pressures and temperatures as well as isentropic and used enthalpy drops are presented during idling, heating up and during transition to operation speed of the turbine. Specifically problems with enthalpy drops and thus efficiency measurement are described in detail.
Topics
Enthalpy
REFERENCES
1.
2.
M.
Banaskiewcz
, Steam Turbine Starts-up
(Transactions of the Institute of Fluid-Flow Machinery, The Szewalski Institute for Fluid-Flow Machinery
, Gdansk
, 2014
), pp. 169
–198
.3.
A.
Ehrsam
et al., “Steam Turbine Start-Up Optimization Tool based on ABAQUS and Python Scripting
,” in Simulia Customer Conference
, (London, UK
, 2009
).4.
J.
Spelling
et al., “Thermal Modeling of a Solar Steam Turbine With a Focus on Start-Up Time Reduction,” in J. Eng. Gas Turbines Power
, edited by (ASME
, 2011
)5.
F.
Alobaid
, Modeling and investigation start-up procedures of a combined cycle power plant
. (Journal of Applied Energy
, Volume 85
, Issue 12
, Elsevier, 2008
), pp. 1173
–1189
6.
P.
Albert
, Steam Turbine Thermal Evaluation and Assessment
(PowerGen, GE Power Systems
, Schenectady
, 2012
)
This content is only available via PDF.
© 2017 Author(s).
2017
Author(s)