The ARIEL project at TRIUMF requires a 50 MeV superconducting electron linac consisting of five nine cell 1.3 GHz cavities divided into three cryomodules with one, two and two cavities in each module respectively. LHe is distributed in parallel to each module at 4 K and at ∼1.2 bar. Each module has a cryogenic insert on board that receives the 4 K liquid and produces 2 K into a cavity phase separator. The module combines a 4 K phase separator, a plate and fin heat exchanger from DATE and a J-T valve expanding into the 2 K phase separator. The unit also supplies 4 K liquid to thermal intercepts in the module in siphon loops that return the vaporized liquid to the 4 K reservoir. For testing purposes the unit is outfitted with a dummy 2 K phase separator and thermal intercepts with variable heaters that mimic the final heat loads in order to test the cryogenic performance. The design of the 4 K / 2 K insert, the results of the cold tests and a summary of the test infrastructure including cryogenics services will be presented.
Skip Nav Destination
,
,
,
,
,
,
,
,
Article navigation
29 January 2014
ADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference - CEC
17–21 June 2013
Anchorage, Alaska, USA
Research Article|
January 29 2014
Cryogenic test of the 4 K / 2 K insert for the ARIEL e-Linac cryomodule Free
R. E. Laxdal;
R. E. Laxdal
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
Y. Ma;
Y. Ma
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
P. Harmer;
P. Harmer
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
D. Kishi;
D. Kishi
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
A. Koveshnikov;
A. Koveshnikov
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
N. Muller;
N. Muller
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
A. Vrielink;
A. Vrielink
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
Search for other works by this author on:
M. O'Brien;
M. O'Brien
University of British Columbia, Vancouver,
Canada
Search for other works by this author on:
M. Ahammed
M. Ahammed
Variable Energy Cyclotron Center, Kolkata,
India
Search for other works by this author on:
R. E. Laxdal
Y. Ma
P. Harmer
D. Kishi
A. Koveshnikov
N. Muller
A. Vrielink
M. O'Brien
M. Ahammed
TRIUMF, 4004 Wesbrook Mall, Vancouver, BC,
Canada
AIP Conf. Proc. 1573, 1184–1191 (2014)
Citation
R. E. Laxdal, Y. Ma, P. Harmer, D. Kishi, A. Koveshnikov, N. Muller, A. Vrielink, M. O'Brien, M. Ahammed; Cryogenic test of the 4 K / 2 K insert for the ARIEL e-Linac cryomodule. AIP Conf. Proc. 29 January 2014; 1573 (1): 1184–1191. https://doi.org/10.1063/1.4860840
Download citation file:
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Classification data mining with Laplacian Smoothing on Naïve Bayes method
Ananda P. Noto, Dewi R. S. Saputro
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Related Content
Overview of the cryogenic system for the ariel e-linac at TRIUMF
AIP Conf. Proc. (June 2012)
Progress update on cryogenic system for ARIEL E-linac at TRIUMF
AIP Conf. Proc. (January 2014)
Thermal Performance of the SNS Cryomodule
AIP Conf. Proc. (June 2004)
Design and commissioning of vertical test cryostats for XFEL superconducting cavities measurements
AIP Conf. Proc. (January 2014)
Specification and design of a 2 K helium system for cryomodule and cavity tests at FRIB
AIP Conf. Proc. (June 2012)