was produced in a liquid target loaded with a molybdenum-salt solution. This novel technique allows for the irradiation of metals dissolved in a liquid solution, normally only available in metal powder or foil form. By using this approach, the existing liquid targets and transfer infrastructure of many PET cyclotrons can be used to produce radiometals, avoiding the need, expense and challenges of operating solid targets. Such an approach allows for rapid testing of new isotopes for proof of feasibility studies. Different concentrations of Mo solution and their effect on the target performance were tested. Sufficient quantities to allow for preclinical studies were produced.