In this work we have compared the experimental results from the thermocline tank of STONE installation of CEA with an analytical model which considers an algebraic sigmoid as solution for the energy balance equation. The parameters of this function have been obtained by fitting its mathematical expression to the experimental temperature-time data for different tank heights. From that fitting physical parameters like the velocity of thermocline zone inside the tank and the effective heat capacity of the storage medium could be determined. These values depend on operating conditions like superficial oil velocity and temperature range but they deviate from the theoretical ones due to the specific STONE tank design in which metallic wall shares 10 % tank volume. In this way, considering or not the tank wall in the effective heat capacity leads to 6.6 % error when predicting the thermocline zone position with the model. However, for thermocline tanks with larger volumes the effect of walls is expected to be negligible and hence the analytical model will be able to predict more accurately their performance.
Research Article|
November 08 2018
Analysis of packed-bed thermocline storage tank performance by means of a new analytical function
Rocío Bayón;
Rocío Bayón
a)
1
CSSU-Thermal Storage, CIEMAT-PSA
, Av. Complutense 40, 28040 Madrid, (Spain
)a)Corresponding author: [email protected]
Search for other works by this author on:
Esther Rojas
Esther Rojas
b)
1
CSSU-Thermal Storage, CIEMAT-PSA
, Av. Complutense 40, 28040 Madrid, (Spain
)
Search for other works by this author on:
Rocío Bayón
1,a)
Esther Rojas
1,b)
1
CSSU-Thermal Storage, CIEMAT-PSA
, Av. Complutense 40, 28040 Madrid, (Spain
)
a)Corresponding author: [email protected]
AIP Conf. Proc. 2033, 090002 (2018)
Citation
Rocío Bayón, Esther Rojas; Analysis of packed-bed thermocline storage tank performance by means of a new analytical function. AIP Conf. Proc. 8 November 2018; 2033 (1): 090002. https://doi.org/10.1063/1.5067096
Download citation file: