The Planck satellite is a project of the European Space Agency based on a wide international collaboration, including United States and Canadian laboratories. It is dedicated to the measurement of the anisotropy of the Cosmic Microwave Background (CMB) with unprecedented sensitivity and angular resolution. The detectors of its High frequency Instrument (HFI) are bolometers cooled down to 100 mK. Their sensitivity will be limited by the photon noise of the CMB itself at low frequencies, and of the instrument background at high frequencies. The requirements on the measurement chain are directly related to the strategy of observation used for the satellite. Due to the scanning on the sky, time features of the measurement chain are directly transformed into angular features in the sky maps. This impacts the bolometer design as well as other elements: For example, the cooling system must present outstanding temperature stability, and the amplification chain must show, down to very low frequencies, a flat noise spectrum.
Skip Nav Destination
Article navigation
8 May 2002
EXPERIMENTAL COSMOLOGY AT MILLIMETRE WAVELENGTHS: 2K1BC Workshop
9-13 July 2001
Breuil-Cervinia (AO), Valle d’Aosta (ITALY)
Research Article|
May 08 2002
The high frequency instrument of Planck: Requirements and design
J. M. Lamarre;
J. M. Lamarre
1Laboratoire d’Etude du rayonnement et de la Matière en Astrophysique, Observatoire de Paris, 61 Bd de l’Observatoire, 75014 Paris. Institut d’Astrophysique Spatiale, Orsay, France
Search for other works by this author on:
B. Maffei;
B. Maffei
2Cardiff University, Wales, United Kingdom
Search for other works by this author on:
P. A. R. Ade;
P. A. R. Ade
2Cardiff University, Wales, United Kingdom
Search for other works by this author on:
M. Piat;
M. Piat
1Laboratoire d’Etude du rayonnement et de la Matière en Astrophysique, Observatoire de Paris, 61 Bd de l’Observatoire, 75014 Paris. Institut d’Astrophysique Spatiale, Orsay, France
Search for other works by this author on:
J. Bock;
J. Bock
3Jet Propulsion Laboratory, Pasadena, California
Search for other works by this author on:
J. L. Puget;
J. L. Puget
1Laboratoire d’Etude du rayonnement et de la Matière en Astrophysique, Observatoire de Paris, 61 Bd de l’Observatoire, 75014 Paris. Institut d’Astrophysique Spatiale, Orsay, France
Search for other works by this author on:
P. de Bernardis;
P. de Bernardis
4Universita La Sapienza, Roma, Italy
Search for other works by this author on:
J. P. Torre;
J. P. Torre
8Service d’Aéronomie, Verrières le Buisson, France
Search for other works by this author on:
F. R. Bouchet;
F. R. Bouchet
10Institut d’Astrophysique de Paris, France
Search for other works by this author on:
R. Sudiwala;
R. Sudiwala
2Cardiff University, Wales, United Kingdom
Search for other works by this author on:
V. Yourchenko
V. Yourchenko
7University of Maynooth, Ireland
Search for other works by this author on:
AIP Conf. Proc. 616, 213–218 (2002)
Citation
J. M. Lamarre, B. Maffei, P. A. R. Ade, M. Piat, J. Bock, J. L. Puget, P. de Bernardis, M. Giard, A. Lange, A. Murphy, J. P. Torre, A. Benoit, R. Bhatia, F. R. Bouchet, R. Sudiwala, V. Yourchenko; The high frequency instrument of Planck: Requirements and design. AIP Conf. Proc. 8 May 2002; 616 (1): 213–218. https://doi.org/10.1063/1.1475631
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Students’ mathematical conceptual understanding: What happens to proficient students?
Dian Putri Novita Ningrum, Budi Usodo, et al.
Related Content
Use of high sensitivity bolometers for astronomy: Planck high frequency instrument
AIP Conference Proceedings (February 2002)