The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.
Skip Nav Destination
Article navigation
10 May 2002
ADVANCES IN CRYOGENIC ENGINEERING: Proceedings of the Cryogenic Engineering Conference - CEC
16-20 July 2001
Madison, Wisconsin (USA)
Research Article|
May 10 2002
He II heat exchanger test unit for the LHC inner triplet
Ch. Darve;
Ch. Darve
1Fermi National Accelerator Laboratory, Batavia, Illinois 60510
Search for other works by this author on:
E. Blanco;
E. Blanco
2CERN, European Organization for Particle Physics
Search for other works by this author on:
Y. Huang;
Y. Huang
1Fermi National Accelerator Laboratory, Batavia, Illinois 60510
Search for other works by this author on:
T. Nicol;
T. Nicol
1Fermi National Accelerator Laboratory, Batavia, Illinois 60510
Search for other works by this author on:
T. Peterson;
T. Peterson
1Fermi National Accelerator Laboratory, Batavia, Illinois 60510
Search for other works by this author on:
Rob van Weelderen
Rob van Weelderen
2CERN, European Organization for Particle Physics
Search for other works by this author on:
AIP Conf. Proc. 613, 147–154 (2002)
Citation
Ch. Darve, E. Blanco, Y. Huang, T. Nicol, T. Peterson, Rob van Weelderen; He II heat exchanger test unit for the LHC inner triplet. AIP Conf. Proc. 10 May 2002; 613 (1): 147–154. https://doi.org/10.1063/1.1472016
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Students’ mathematical conceptual understanding: What happens to proficient students?
Dian Putri Novita Ningrum, Budi Usodo, et al.
Related Content
Non-linear advanced control of the LHC inner triplet heat exchanger test unit
AIP Conference Proceedings (May 2002)
Two low-cost, modular sub-λ test cryostats
AIP Conference Proceedings (January 2014)
COMMISSIONING AND FIRST OPERATION OF THE LOW‐BETA TRIPLETS AND THEIR ELECTRICAL FEED BOXES AT THE LARGE HADRON COLLIDER
AIP Conference Proceedings (April 2010)
An Update for the MuCool Test Area
AIP Conference Proceedings (April 2006)
Automatic Management Systems for the Operation of the Cryogenic Test Facilities for LHC Series Superconducting Magnets
AIP Conference Proceedings (April 2006)