The whole TEXTOR-94 ICRF system [1,2] circuit has been analyzed, partially modelled and studied at the fundamental operating frequency and, more important, at harmonic frequencies thereof. It has been found that without appropriate measures, present day systems and especially the TEXTOR ICRF system are prone to spurious generation of power at the second harmonic frequency. This leads either to erroneous activation of the reflected power safety protection or to highly increased (in some cases doubled) voltages in the transmission lines and antennas. As the voltage standing waves at the second harmonic displace the total voltage maxima in the transmission lines and antennas, this also explains why arcs are not always found at the expected voltage maxima for the fundamental frequency. The model is also able to give additional explanations why the ASDEX-Upgrade ICRF system has dramatically improved its power handling capabilities after the introduction of the “3dB coupler reflection compensation scheme” [3,4]. The output of one of the TEXTOR transmitters has been fitted with a quarter wave length shorted stub which has no effect on the operation at the fundamental frequency but which effectively shorts out the second harmonic. It has to be noted that eg. the Tore Supra RDL [5] antennas are fitted with such a stub in the feeding transmission line whose function is to enter cooling water into the transmission line system. Hence, this could be the explanation of the apparent higher than average power handling capabilities of the TS antenna system. Experimental results clearly indicate a much improved operational power handling capability on plasma and an increased voltage stand-off when conditioning this antenna pair on vacuum. Limits have yet to be explored but already remarkable is the fact that since the installation of the quarter wavelength stub the reflected power safety system has been activated only once and furthermore so in poorly matched conditions.
Skip Nav Destination
Article navigation
20 September 1999
The thirteenth topical conference on radio frequency power in plasmas
12-14 April 1999
Annapolis, Maryland (USA)
Research Article|
September 20 1999
Generation of harmonic frequencies and their effects in present day ICRF systems
F. Durodié;
F. Durodié
Laboratorium voor Plasma Fysica-Laboratoire de Physique des Plasmas Associatie «EURATOM-Belgische Staat»-Association «EURATOM-État Belge» Koninklijke Militaire School-Ecole Royale Militaire Renaissancelaan 30-B-1000 Brussels-30, Av. de la Renaissance
Search for other works by this author on:
M. Vervier
M. Vervier
Laboratorium voor Plasma Fysica-Laboratoire de Physique des Plasmas Associatie «EURATOM-Belgische Staat»-Association «EURATOM-État Belge» Koninklijke Militaire School-Ecole Royale Militaire Renaissancelaan 30-B-1000 Brussels-30, Av. de la Renaissance
Search for other works by this author on:
AIP Conf. Proc. 485, 457–461 (1999)
Citation
F. Durodié, M. Vervier; Generation of harmonic frequencies and their effects in present day ICRF systems. AIP Conf. Proc. 20 September 1999; 485 (1): 457–461. https://doi.org/10.1063/1.59707
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
5
Views
Citing articles via
Related Content
RF Arc Detection in ICRH RDL Antennas by Phase Measurement
AIP Conference Proceedings (November 2009)
Modeling of compact loop antennas
AIP Conference Proceedings (September 1987)
Electrical details of the ICRH resonant double loop matching sections of ITER
AIP Conference Proceedings (April 1997)
Unraveling metallic contaminants in complex polyimide heterostructures using deep ultraviolet spectroscopic ellipsometry
Appl. Phys. Lett. (September 2023)
Limitations on temporal processing by cochlear implant users
J Acoust Soc Am (April 2016)