The results of visual and technical examination of a brick building were used as initial information for assessing the technical condition of structures and building materials. The investigated one-story non-residential building was built more than forty-five years ago. The obtained results of the analysis showed that the load-bearing structures of the building are in a limited working condition, and their operational reliability and durability as a whole do not meet the requirements of the current regulatory documents. While monitoring the technical condition of the building, defects and damages that occurred at the stage of building construction and during its operation were revealed. Based on the analysis of the load-bearing structures survey, a conclusion on its operational reliability was formulated and recommendations to ensure further normal operation were developed. It was noted that after the repair work completion and during the further operation of the studied brick building, it will be necessary to comply with the requirements for planned preventive maintenance according to the current building codes. The analysis of the possibility of the second-floor superstructure on existing structures is carried out. It is noted that now it is impossible to carry out the superstructure, since before it is completed, the recommended work on strengthening the structures should be carried out in order to ensure safety during operation of the lower floor in case of an increase in the load on it from the additionally constructed second floor.
Skip Nav Destination
Article navigation
27 March 2024
PROCEEDINGS OF THE V INTERNATIONAL SCIENTIFIC CONFERENCE ON ADVANCED TECHNOLOGIES IN AEROSPACE, MECHANICAL AND AUTOMATION ENGINEERING: (MIST: Aerospace-V 2023)
3–5 March 2023
Krasnoyarsk, Russian Federation
Research Article|
March 27 2024
Structural condition assessment of a single-storey non-residential building
Svetlana Sazonova;
Svetlana Sazonova
a)
1
Department of Technosphere and Fire Safety, Voronezh State Technical University
, 84 October 20th Anniversary Street, Voronezh, 394006, Russia
a)Corresponding author: [email protected]
Search for other works by this author on:
Sergey Nikolenko;
Sergey Nikolenko
b)
1
Department of Technosphere and Fire Safety, Voronezh State Technical University
, 84 October 20th Anniversary Street, Voronezh, 394006, Russia
Search for other works by this author on:
Vladimir Zolnikov;
Vladimir Zolnikov
c)
2
Basic Department of Technical and Software Support of Computing and Information Systems, Voronezh State Forestry University named after G. F. Morozov
, 8 Timiryazev Street, Voronezh, 394087, Russia
Search for other works by this author on:
Alexander Achkasov;
Alexander Achkasov
d)
2
Basic Department of Technical and Software Support of Computing and Information Systems, Voronezh State Forestry University named after G. F. Morozov
, 8 Timiryazev Street, Voronezh, 394087, Russia
Search for other works by this author on:
Philip Makarenko;
Philip Makarenko
e)
2
Basic Department of Technical and Software Support of Computing and Information Systems, Voronezh State Forestry University named after G. F. Morozov
, 8 Timiryazev Street, Voronezh, 394087, Russia
Search for other works by this author on:
Dmitry Sysoev;
Dmitry Sysoev
f)
3
Department of Innovatics and Construction Physics Named after Professor I S Surovtsev, Voronezh State Technical University
, 84 October 20th Anniversary Street, Voronezh, 394006, Russia
Search for other works by this author on:
Leonid Stenyukhin
Leonid Stenyukhin
g)
4
Department of Applied Mathematics and Mechanics, Voronezh State Technical University
, 84 October 20th Anniversary Street, Voronezh, 394006, Russia
Search for other works by this author on:
AIP Conf. Proc. 3102, 020007 (2024)
Citation
Svetlana Sazonova, Sergey Nikolenko, Vladimir Zolnikov, Alexander Achkasov, Philip Makarenko, Dmitry Sysoev, Leonid Stenyukhin; Structural condition assessment of a single-storey non-residential building. AIP Conf. Proc. 27 March 2024; 3102 (1): 020007. https://doi.org/10.1063/5.0199709
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
25
Views
Citing articles via
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Students’ mathematical conceptual understanding: What happens to proficient students?
Dian Putri Novita Ningrum, Budi Usodo, et al.
Related Content
Technical monitoring of objects in the zone of new construction influence
AIP Conf. Proc. (March 2024)
Forecasting of the fire situation at an industrial facility
AIP Conf. Proc. (March 2023)
Dynamic absorber design for experimental two storey building model
AIP Conference Proceedings (September 2012)
Analysis of seismic forces at different floor levels of G+9 multi-storey OMRF building using STAAD Pro
AIP Conference Proceedings (November 2022)
Structural deformation of staff’s quarters SMK ranau subjected to the 2015 Ranau earthquake using Ruaumoko 2D
AIP Conf. Proc. (October 2018)