Blind source separation (BSS) is extracting a set of source signals from a group of mixed signals without knowledge about the original source signals or the mixing process. Nowadays, Blind Source Separation algorithms and different denoising methods are widely used in Biomedical Signal Processing applications. Fast ICA algorithm is one of the BSS algorithms that extract fetal heart sound from noisy single-channel abdominal phonocardiograms of pregnant women. This work implements the Savitzky-Golay Filtering method and Fast ICA BSS algorithm for signal enhancement on a portable device, Raspberry Pi, after the validation in Python and evaluates the performance of fetal Heart Sound extraction from mixed single channel abdominal PCG. The experiments on single channel abdominal PCG from pregnant women between 36th to 40th week of pregnancy are used to evaluate the methods. The results shows that this method extracts fetal heart sound from maternal abdominal PCG signal with a higher Signal-to-Noise ratio.

1.
E. A.
Ibrahim
,
S.
Al Awar
,
Z. H.
Balayah
,
L. J.
Hadjileontiadis
, and
A. H.
Khandoker
, “
A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography
,”
Frontiers in Physiology
, vol.
8
, p.
764
, (Oct.
2017
).
2.
M.
Moghavvemi
,
B.
Tan
, and
S.
Tan
, “
A non-invasive PC-Based measurement of Fetal phonocardiography
,”
Sensors
, vol.
107
, no.
1
, pp.
96
103
, (Oct.
2003
).
3.
M.
Cesarelli
,
M.
Ruffo
,
M.
Romano
, and
P.
Bifulco
, “
Simulation of feotal phonocardiographic recordings for testing of FHR extraction algorithms
,”
Computer Methods and Programs in Biomedicine
, vol.
107
, no.
3
, pp.
513
523
, (Sep.
2012
).
4.
P.
Zhang
,
S.
Ye
,
Z.
Huang
,
D.
Jiaerken
,
S.
Zhao
,
L.
Zhang
, and
J.
Wu
, “A Noninvasive Continuous Fetal Heart Rate Monitoring System for Mobile Healthcare Based on Fetal Phonocardiography,” in
Advances in Body Area Networks
I.,
G.
Fortino
and
Z.
Wang
, Eds.
Cham
:
Springer International Publishing
, (
2019
), pp.
191204
.
5.
P.
Varady
,
L.
Wildt
,
Z.
Beny
o, and
A.
Hein
, “
An ad vanced method in fetal phonocardiography
,”
Computer Methods and Programs in Biomedicine
, vol.
71
, no.
3
, pp.
283
296
, (Jul.
2003
).
6.
R.
Martinek
,
J.
Nedoma
,
M.
Fajkus
,
R.
Kahankova
,
J.
Konecny
,
P.
Janku
,
S.
Kepak
,
P.
Bilik
, and
H.
Nazeran
A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring
,”
Sensors
, vol.
17
, no.
4
, p.
890
, (Apr.
2017
).
7.
V.
Padmanabhan
,
J.
Semmlow
, and
W.
Welkowitz
, “
Accelerometer type cardiac transducer for detection of low-level heart sounds
,”
IEEE Transactions on Biomedical Engineering
, vol.
40
, no.
1
, pp.
21
28
, (Jan.
1993
).
8.
J.
Kolarik
,
M.
Golembiovsky
,
T.
Docekal
,
R.
Kahankova
,
R.
Martinek
, and
M.
Prauzek
, “
A Low-Cost Device for Fetal Heart Rate Measurement
,”
IFACPapers OnLine
, vol.
51
, no.
6
, pp.
426
431
, (
2018
).
9.
P.
Varady
, “
Wavelet-based adaptive denoising of phonocardiographic records
,”
Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology
, (
2001
)
10.
S.
Vaisman
,
S. Yaniv
Salem
,
G.
Holcberg
, and
A. B.
Geva
, “
Passive fetal monitoring by adaptive wavelet denoising method
,”
Computers in Biology and Medicine
, vol.
42
, no.
2
, pp.
171
179
, (Feb.
2012
).
11.
R.
Sameni
, &
Samieinasab
,
M.
Shiraz University Fetal Heart Sounds Database (version 1.0.1
).
PhysioNet.
(
2001
)
12.
Wang
Haibin
and
Hu
Yuliang
Heart Sound Measurement and Analysis System with Digital Stethoscope
Asia International Symposium on Mechatronics
,
27-31
(Aug.
2008
).
13.
Jimenez-Gonzalez
and
C. J.
James
, “
Blind source separation to extract fetal heart sounds from noisy abdominal phonograms: a single channel method
,”
4th IET International Conference on Advances in Medical, Signal and Information Processing (MEDSIP)
, (
2008
), pp.
1
4
.
14.
A.
Jimenez-Gonzalez
and
C. J.
James
, “
Source separation of Foetal Heart Sounds and maternal activity fromsingle channel phonograms: A temporal independent component analysis approach
,”
Computers in Cardiology
, (
2008
), pp.
949
952
.
15.
Jimenez-Gonzalez
and
C. J.
James
, “
Extracting sources from noisy abdominal phonograms: a single channel blind source separation method
,”
Med. Biol. Eng. Comput.
, vol.
47
, no.
6
, pp.
655
664
, (Jun.
2009
).
16.
Yuan-Hsiang
Lin
,
Chih-Fong
Lin
,
Chien-Chih
Chan
, and
He-Zhong
You
, “
Design and implementation of a remote embedded DSP stethoscope with a method for judging heart murmur
”,
IEEE conference on Instrumentation and Measurement Technology
, (Jun.
2009
).
17.
Ravindra Manohar
Potdar
,
Mekhram
Meshram
and
Ramesh
Kumar
, “
Design and Analysis of a PCG Acquisition and Denoising Circuit
”,
Turkish Journal of Physiotherapy and Rehabilitation
;
32
(
3
) ISSN 2651-4451, (May
2021
), ISSN 2651-446X.
18.
D.D.
Patil
, and
R. K.
Shastri
. “
Design of wireless electronic stethoscope based on zigbee
.”
International Journal of Distributed and Parallel systems
abs/1202.1680(1) Source DBLP, arXiv:1202.1680 (
2012
).
19.
R. M.
Potdar
,
Mekhram
Meshram
and
Ramesh
Kumar
A Review Based Design and Implementation of Electronic Stethoscope for Heart Sound Analysis
.”
International Journal of EngineeringDevelopment and Research,© 2015 IJEDR
, Volume
3
, Issue
2
, ISSN: 2321-9939, (
2015
).
20.
J. Dhoulath
Beegum
Separation of power-line noise from tinnitus sound, to aid medical diagnoses
”,
Science Direct, Perspectives in Science, Elsevier
, (
2016
).
21.
J. Dhoulath
Beegum
and
D.
Chithraprasad
, “
Testing of Dhoulath’s method to speed up diagnose by separating up crying sound of a baby from normal heart beats - ‘An innovative time saving technique
”,
Science Direct, Perspectives in Science, Elsevier
, (
2016
).
22.
J. Dhoulath
Beegum
and
D.
Chithraprasad
, “
Testing Dhoulath’s method - An investigative probe into mortality rate to aid diagnoses
”,
Science Direct, Perspectives in Science, Elsevier
, (
2016
).
23.
J. Dhoulath
Beegum
and
Deepika
Sasi
.
”Novelimplementation of Filtered-Reconstruction ICA enabled wheeze component separation for preliminary diagnosis of COVID-19
”.
Journal of Interdisciplinary Mathematics
,
24
,
353
366
, (
2021
).
24.
J. Dhoulath
Beegum
,
D.
Chithraprasad
,
Sajeev
Ampadi
and
Mahesh
Sankar
.
”A pragmatic study on patient friendly treatment: Implementing Dhoulath’s method for separation of cardiac signals from speech for cases including COVID-19 patients
”.
Journal of Statistics and Management Systems
, (
2021
).
25.
J. Dhoulath
Beegum
and
D.
Chithraprasad
, “
Snore Sound Separation of Enlarged Adenoid From Normal Heart sound using Blind Source Separation
”,
International Journal of Computer Applications
(ISSN 0975-8887) (
2012
).
26.
J. Dhoulath
Beegum
and
D.
Chithraprasad
,
”Statistical analysis of blind source separated heart beat and snore sound
”, Volume
5
,
International Journal Of Advanced Research In Engineering And Technology (IJARET)
. ISSN:0976-6480
27.
J. Dhoulath
Beegum
,
D.
Chithraprasad
,
Sajeev
Ampadi
,
Ramesh Chandra
Poonia
and
Mahesh
Sankar
Blind separation of speech from aortic regurgitation signals using Dhoulath’s method
”,
Journal of Experimental & Theoretical Artificial Intelligence
, (
2022
).
28.
M.
Martinez
,
J.
Calpe
,
E.
Soria
,
J.
Guerrero
,
G.
Campsand
,
L.
Gomez
Methods to evaluate the performance of fetal electrocardiogram extraction algorithms
,” in
Computers in Cardiology2001.
Vol.
28
(Cat.No. 01CH37287).
Rotterdam, Netherlands
:
IEEE
, (
2001
), pp.
253
256
.
29.
F´evotte
,
R.
Gribonval
and
E.
Vincent
, BSS EVAL Toolbox User Guide,
IRISA Technical Report
1706,
Rennes
,
France
, (Apr.
2005
).
30.
J.
Gong
,
Nie
S.
and
Wang
Y.
An Improved Empirical Mode Decomposition Algorithm for Phonocardiogram Signal De-noising and Its Application in S1/S2 Extraction
”.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi.
(Oct
2015
);
32
(
5
):
970
4
. Chinese. PMID: 26964297.
This content is only available via PDF.
You do not currently have access to this content.