Revision total knee arthroplasties cause performed aseptic loosening, instability, and polyethylene wear. The collaboration between surgeons and engineers for resulted in many developments in prosthesis design is needed. Separation or removal of the femoral component has been observed and this has the potential to severely damage the polyethylene component. In most cases 90% of the patients examined experienced significant medial or lateral condylar lift at some stage during the gait cycle. Using the MRI, a normal knee has maximum lateral lift is approx. 6.7 mm and maximum medial lift is approx. 2.1 mm, when a varus strees was applied at a 90° knee flexion. Elevation of the medial condyle due to varus malalignment will distribute more contact force on the lateral condyle. In this study, a polyethylene component of a posterior-stabilized right knee joint implant was developed to facilitate a high range of motion (ROM). Malalignment varus was observed with the axes of knee motion joint implants were varied from 0, 2, 3 to 5° and knee bend measurements at 30, 60, 90, 120, and 150° of knee flexion. Using the knee kinematic motion simulator, the modified polyethylene component resulted in 0° malalignment there is no gap of the femoral component with the polyethylene component, from 30 to 150° of knee flexion. At 2° malalignment, the femoral component was raised by 0.5 mm at a 120 to 150° knee flexion and increased with increasing knee flexion. Maximum gap occurs at 5° malalignment in the amount of 2 mm at 150° of knee flexion. The aim of this study was therefore to evaluation malalignment varus of the flexed knee using knee kinematic motion simulator, with reference to the tibiofemoral flexion gap. The result that the modified design is expected in a narrow down gap between femoral and polyethylene component to accommodate deep knee flexion movement in daily activities and reduce the possibility of subluxation and dislocation at the polyethylene component during deep knee flexion. Widest gap between femoral component and the polyethylene component more contact force on the lateral condyle increases potential wear or fracture the polyethylene.
Skip Nav Destination
Article navigation
28 February 2024
5TH INTERNATIONAL SEMINAR ON METALLURGY AND MATERIALS (ISMM2022): Strengthening research and innovation in metallurgy and materials for sustainable economic development
22–23 November 2022
Tangerang Selatan, Indonesia
Research Article|
February 28 2024
Evaluation varus stress in total knee arthroplasty designed for deep knee flexion using knee kinematic motion simulator
Joko Triwardono;
Joko Triwardono
a)
1
Research Center for Metallurgy – National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.a)Corresponding author: [email protected]
Search for other works by this author on:
Harry Purnama;
Harry Purnama
b)
2
Research Centre for Process and Manufacturing Industry Technology - National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.
Search for other works by this author on:
Wahyu Sulistyo;
Wahyu Sulistyo
c)
3
Research Center for Strenght Structure – National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.
Search for other works by this author on:
Fendy Rokhmanto;
Fendy Rokhmanto
d)
1
Research Center for Metallurgy – National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.
Search for other works by this author on:
Rahadian Roberto;
Rahadian Roberto
e)
1
Research Center for Metallurgy – National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.
Search for other works by this author on:
Ika Kartika;
Ika Kartika
f)
1
Research Center for Metallurgy – National Research and Innovation Agency
, KST B.J. Habibie, South Tangerang, Indonesia
.
Search for other works by this author on:
Sugeng Supriadi
Sugeng Supriadi
g)
4
Department of Mechanical Engineering, Universitas Indonesia
, Depok, West Java, Indonesia
.
Search for other works by this author on:
AIP Conf. Proc. 3003, 020111 (2024)
Citation
Joko Triwardono, Harry Purnama, Wahyu Sulistyo, Fendy Rokhmanto, Rahadian Roberto, Ika Kartika, Sugeng Supriadi; Evaluation varus stress in total knee arthroplasty designed for deep knee flexion using knee kinematic motion simulator. AIP Conf. Proc. 28 February 2024; 3003 (1): 020111. https://doi.org/10.1063/5.0186315
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
30
Views
Citing articles via
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Students’ mathematical conceptual understanding: What happens to proficient students?
Dian Putri Novita Ningrum, Budi Usodo, et al.
Related Content
Virtual three-dimensional kinematics comparison between normal healthy knee and tumor-suffered knee post resection with mega prosthesis reconstructed
AIP Conf. Proc. (March 2024)
Pressure mapping at orthopaedic joint interfaces with fiber Bragg gratings
Appl. Phys. Lett. (February 2006)
A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients
AIP Conf. Proc. (December 2024)
Optimation of single radius system design on total knee arthroplasty for Indonesian’s need
AIP Conf. Proc. (January 2025)
Effect of acupuncture and moxibustion on functional recovery after knee arthroplasty
AIP Conf. Proc. (February 2019)