Plantar pressure distributions are essential and valuable measures in sports shoe assessment, diabetic ulcer detection, clinical gait analysis, pathological foot diagnosis, and medical orthotic fabrication. However, current plantar pressure measurement and examination systems are less comfortable to wear and expensive. This paper presents the measurement and analysis of plantar pressure inside the shoe, a system based on a set of sensors for plantar pressure and blood oxygen saturation built into the shoe, which is soft and light, has high-pressure sensitivity, and predicts the possibility of ulcer formation. The sensors connect to the Mega 2560 microcontroller to obtain data from the sensors inside the insole and transmit the data wirelessly via the Internet of Things technology to the smart mobile phone via Wi-Fi, an alarm is sent to the user interface to notify the user or health care providers, the alerts will be set according to the values of Sensors to inform the user of the ultimate risk of disease caused by these parameters. The system can be conveniently configured to operate in research laboratories, hospitals, sports stadiums, and other out-of-door environments. After obtaining the results, the sensors supported more than 42% of the body weight, where the accuracy of the sensors was (± 2.04 N ~ 0.20 kg) for the plantar pressure sensor, and (± 2%) for the oxygen saturation sensor.

1.
T. C.
Pataky
,
T.
Mu
,
K.
Bosch
,
D.
Rosenbaum
, and
J. Y.
Goulermas
, "
Gait recognition: highly unique dynamic plantar pressure patterns among 104 individuals
,"
Journal of The Royal Society Interface
, vol.
9
, no.
69
, pp.
790
800
,
2012
.
2.
X.
Dong
,
Y.
Fan
,
M.
Zhang
, and
J.
Chen
, "
Studies on biomechanics of human foot: A review
,"
Sheng
Wu
,
Yi
Xue
,
Gong
Cheng
,
Xue Za
Zhi=
Journal of Biomedical Engineering= Shengwu Yixue Gongchengxue Zazhi
, vol.
19
, no.
1
, pp.
148
153
,
2002
.
3.
S. A.
Bus
,
J. S.
Ulbrecht
, and
P. R.
Cavanagh
, "
Pressure relief and load redistribution by custom-made insoles in diabetic patients with neuropathy and foot deformity
,"
Clinical Biomechanics
, vol.
19
, no.
6
, pp.
629
638
,
2004
.
4.
M. J.
Hessert
,
M.
Vyas
,
J.
Leach
,
K.
Hu
,
L. A.
Lipsitz
, and
V.
Novak
, "
Foot pressure distribution during walking in young and old adults
,"
BMC geriatrics
, vol.
5
, no.
1
, pp.
1
8
,
2005
.
5.
V. H.
Chuter
,
M. J.
Spink
,
M.
David
,
S.
Lanting
, and
A.
Searle
, "
Clinical foot measurements as a proxy for plantar pressure testing in people with diabetes
,"
Journal of foot and ankle research
, vol.
14
, no.
1
, pp.
1
9
,
2021
.
6.
M. J.
Mueller
, "
Application of plantar pressure assessment in footwear and insert design
,"
Journal of orthopaedic & sports physical therapy
, vol.
29
, no.
12
, pp.
747
755
,
1999
.
7.
A. J.
Boulton
et al., "
Dynamic foot pressure and other studies as diagnostic and management aids in diabetic neuropathy
,"
Diabetes care
, vol.
6
, no.
1
, pp.
26
33
,
1983
.
8.
C. A.
Abbott
et al., "
Site-Specific, Critical Threshold Barefoot Peak Plantar Pressure Associated with Diabetic Foot Ulcer History: A Novel Approach to Determine DFU Risk in the Clinical Setting
,"
Medicina
, vol.
58
, no.
2
, p.
166
,
2022
.
9.
J.
Bae
,
K.
Kong
,
N.
Byl
, and
M.
Tomizuka
, "A mobile gait monitoring system for gait analysis," in
2009 IEEE International Conference on Rehabilitation Robotics
,
2009
:
IEEE
, pp.
73
79
.
10.
S.
Ostadabbas
,
A.
Saeed
,
M.
Nourani
, and
M.
Pompeo
, "Sensor architectural tradeoff for diabetic foot ulcer monitoring," in
2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
,
2012
:
IEEE
, pp.
6687
6690
.
11.
P. R.
Cavanagh
,
F. Hewitt
Jr
, and
J.
Perry
, "
In-shoe plantar pressure measurement: a review
,"
The foot
, vol.
2
, no.
4
, pp.
185
194
,
1992
.
12.
E.
Morales-Orcajo
,
R. Becerro de Bengoa
Vallejo
,
M. Losa
Iglesias
,
J.
Bayod
, and
E. Barbosa de Las
Casas
, "
Foot internal stress distribution during impact in barefoot running as function of the strike pattern
,"
Computer Methods in Biomechanics and Biomedical Engineering
, vol.
21
, no.
7
, pp.
471
478
,
2018
.
13.
M.
Nouman
,
W.
Leelasamran
, and
S.
Chatpun
, "
Effectiveness of total contact orthosis for plantar pressure redistribution in neuropathic diabetic patients during different walking activities
,"
Foot & ankle international
, vol.
38
, no.
8
, pp.
901
908
,
2017
.
14.
U. H.
Tang
,
R.
Zügner
,
V.
Lisovskaja
,
J.
Karlsson
,
K.
Hagberg
, and
R.
Tranberg
, "
Foot deformities, function in the lower extremities, and plantar pressure in patients with diabetes at high risk to develop foot ulcers
,"
Diabetic foot & ankle
, vol.
6
, no.
1
, p.
27593
,
2015
.
15.
T.
Mori
,
M.
Hamatani
,
H.
Noguchi
,
M.
Oe
, and
H.
Sanada
, "
Insole-type simultaneous measurement system of plantar pressure and shear force during gait for diabetic patients
,"
Journal of Robotics and Mechatronics
, vol.
24
, no.
5
, pp.
766
772
,
2012
.
16.
F.
Haris
,
A.
Firman
,
K.
Irawati
, and
F. F.
Rahman
, "
Walking speed and insole that reduce plantar pressure in diabetes: a review
,"
Journal of Indonesian Wound Ostomy Continence Nurses Association
, vol.
1
, no.
1
, pp.
21
41
,
2022
.
17.
F.
Haris
et al., "
A Review of the Plantar Pressure Distribution Effects from Insole Materials and at Different Walking Speeds
,"
Applied Sciences
, vol.
11
, no.
24
, p.
11851
,
2021
.
18.
I. E.
Inc
, "
FSR Force Sensing Resistor Integration Guide and Evaluation Parts Catalog
,"
Interlink Electronics
,
2014
.
19.
Maxim Integrated High-Sensitivity Pulse Oximeter and Heart-Rate Sensor for Wearable Health
, vol. Rev 1; 10/18
2018
.
20.
J. A.
Akambase
,
T. V.
Kokoreva
,
O. A.
Gurova
, and
J. A.
Akambase
, "
The effect of body positions on foot types: Considering body weight
,"
Translational Research in Anatomy
, vol.
16
, p.
100048
,
2019
.
21.
Z.
Jin
, "
Instrumented parallel bars for three-dimensional force
,"
Journal of rehabilitation research and development
, vol.
29
, no.
2
,
1992
.
22.
M. E.
Fernando
et al., "
Plantar pressures are higher in cases with diabetic foot ulcers compared to controls despite a longer stance phase duration
,"
BMC endocrine disorders
, vol.
16
, no.
1
, pp.
1
10
,
2016
.
23.
K.
Moulaei
,
M.
Malek
, and
A.
Sheikhtaheri
, "
A smart wearable device for monitoring and self-management of diabetic foot: a proof of concept study
,"
International Journal of Medical Informatics
, vol.
146
, p.
104343
,
2021
.
24.
A.
Caselli
,
H.
Pham
,
J. M.
Giurini
,
D. G.
Armstrong
, and
A.
Veves
, "
The forefoot-to-rearfoot plantar pressure ratio is increased in severe diabetic neuropathy and can predict foot ulceration
,"
Diabetes care
, vol.
25
, no.
6
, pp.
1066
1071
,
2002
.
25.
Q.
Mei
et al., "
Foot shape and plantar pressure relationships in shod and barefoot populations
,"
Biomechanics and Modeling in Mechanobiology
, vol.
19
, no.
4
, pp.
1211
1224
,
2020
.
26.
Q. Q.
Shi
,
P. L.
Li
,
K.-L.
Yick
,
N.-W.
Li
, and
J.
Jiao
, "
Effects of contoured insoles with different materials on plantar pressure offloading in diabetic elderly during gait
,"
Scientific reports
, vol.
12
, no.
1
, pp.
1
10
,
2022
.
27.
H.
Korada
,
A.
Maiya
,
S. K.
Rao
, and
M.
Hande
, "
Effectiveness of customized insoles on maximum plantar pressure in diabetic foot syndrome: A systematic review
,"
Diabetes & Metabolic Syndrome: Clinical Research & Reviews
, vol.
14
, no.
5
, pp.
1093
1099
,
2020
.
This content is only available via PDF.
You do not currently have access to this content.