Population growth requires the growth of public facilities. Piping and fire fighting systems are an integral part of these public buildings. The piping system is used to provide clean water and distribute waste water. While the fire extinguishing system is used to extinguish the fire in the event of a fire. From the results of the study, it was found that the need for clean water in Malang Creative Center (MCC), a 7-storey building with 1298 visitors requires 6.49 m3/day of clean water. The capacity of the water tank used is 18 m3, and the Ground Water Tank for Hydrant used is 24 m3. And the results of the analysis required a waste water reservoir (WTP), a container tank with a capacity of 40 m³. So, to transfer clean water to the above reservoir, a pump with a flow capacity specification of 16.2 m³/hour is required and a pump head displacement of 7 until 54 m. For the distribution of clean water using the pressure of gravity from the top water tank to the sanitation equipment on each floor. The fire fighting system uses 2 hydrants placed outside the building and 4 indoor hydrant boxes placed on each floor. The pumps used are electric hydrant fire pump brand Ebara 150X100 FSKA and diesel fire pump brand Ebara 150X100 FSKA.

1.
A. A.
Darmawan
,
M.
Bisri
, and
E.
Suhartanto
, "
Assessment of spatial changes of LULC dynamics, using multi temporal landsat data (case study: Lesti Sub Watershed, Malang Regency, Indonesia)
," vol.
930
, p.
012075
:
IOP Publishing
.
2.
D.
Sugiyono
, "
Metode penelitian pendidikan pendekatan kuantitatif, kualitatif dan R&D
,"
2013
.
3.
J. J.
Susilo
, "
Studi Perencanaan Penyediaan Air Bersih Pada Gedung Bertingkat Tunjungan Plasa VI Kota Surabaya
,"
2014
.
4.
K. C. B.
Artayana
and
G. I.
Atmaja
, “
Perencanaan instalasi air bersih dan air kotor pada bangunan gedung dengan menggunakan sistem pompa
,”
Jurnal Energi dan Manufaktur
,
2010
.
5.
R.
Raškauskaitė
and
V.
Grigonis
, “
An approach for the analysis of the accessibility of fire hydrants in urban territories
,”
ISPRS International Journal of Geo-Information
, vol.
8
, no.
12
, p.
587
,
2019
.
6.
D.
Nurmayadi
and
M. S.
Al Huseiny
, “
Peningkatan Kualitas Keandalan Sarana Dan Pra-Sarana Sistem Proteksi Kebakaran Pasar Tradisional Di Kota Tasikmalaya
,”
Jurnal Arsitektur ARCADE
, vol.
2
, no.
3
, pp.
163
169
,
2018
.
7.
Y. A.
Nurhakim
and
K. S.
Utomo
, “
Water Distribution in a Fire Protection System (Case Study Of DKK Semarang Building Simulation by Epanet 2.0
),"
Jurnal Teknik Sipil dan Perencanaan
, vol.
23
, no.
1
, pp.
64
73
,
2021
.
This content is only available via PDF.
You do not currently have access to this content.