This paper proposes an ANN based adaptive Auto Reclosing AR which integrated of an operation of distance measuring relay in HV Over Head Transmission Line OHTL. This work is brought to enhance stability synchronism, and reliability during the transient faults of OHTL. Thus, it leads to increase the continuity of the electric power system, especially of hydropower plants are connected to utility grid. This work are used Matlab\Simulink environment to design and simulate a single-phase auto-reclosing, which depends on the Artificial Neural Networks ANN integrated with a distance relay DR. In addition, the simulation model consists of Boolean algebra circuits, and timers are utilised to build Auto-reclosure of a circuit breaker in each phase. The ANN is here trained to recognize angle values of actual impedances (in the positive sequence only) in which it can classify which phase exactly is line to ground fault. The simulation results show the ability of this combination to distinguish among various fault types and giving multi pulses-shot of tripping and reclosing for the specific circuit breaker with a successful mechanism. In this paper, a realistic system with real parameters was represented by the important transmission line (Mosul Dam-East Mosul), which currently is only the main and alone line that connects the northern Iraq network with a national grid.
Skip Nav Destination
Article navigation
15 December 2023
1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE DEVELOPMENT TECHNIQUES (ICSDT2022)
29–30 June 2022
Nineveh, Iraq
Research Article|
December 15 2023
Adaptive auto reclosing system for HV transmission lines based on ANN
Mohammed Y. Suliman;
Mohammed Y. Suliman
a
1
Department of Electrical Power Technology Engineering, Technical Engineering College, Northern Technical University
, Mosul, Iraq
aCorresponding author: mohammed.yahya@ntu.edu.iq
Search for other works by this author on:
Ahmed A. Allu;
Ahmed A. Allu
b)
2
Technical Institute, Northern Technical University
, Mosul, Iraq
Search for other works by this author on:
Estabraq A. Jasim
Estabraq A. Jasim
c)
1
Department of Electrical Power Technology Engineering, Technical Engineering College, Northern Technical University
, Mosul, Iraq
Search for other works by this author on:
AIP Conf. Proc. 2862, 020048 (2023)
Citation
Mohammed Y. Suliman, Ahmed A. Allu, Estabraq A. Jasim; Adaptive auto reclosing system for HV transmission lines based on ANN. AIP Conf. Proc. 15 December 2023; 2862 (1): 020048. https://doi.org/10.1063/5.0171479
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Social mediated crisis communication model: A solution for social media crisis?
S. N. A. Hamid, N. Ahmad, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Related Content
Arc fault influence on single-phase auto-reclosing in HV transmission lines
AIP Conf. Proc. (October 2024)
Analysis of the operation of modern fault locators
AIP Conference Proceedings (December 2022)
Influence of the aperiodic component on the short circuit current in electric power system
AIP Conf. Proc. (March 2020)
Reliability evaluation for electrical collector systems of wind farm using the section enumeration technique
J. Renewable Sustainable Energy (September 2013)