This study designed a Series Active Filter (SAF) model with PI tuning using a comparison of the Ant Colony Optimization (ACO) and Particle Swarm Optimisation (PSO) algorithms, which were simulated to compensate for harmonics due to the effect of non-linear loads on the secondary side of the 380 Volt low voltage distribution transformer with a capacity of 32 kVA. The series active filter consists of two main circuits namely the control system and inverter, the control system in computing through the ACO Algorithm for tuning PI values. The result of tuning pi as a reference wave will be compared to spwm carier wave amplitude as a reliable VSI control modulation. This study resulted in a decrease in harmonics in current and voltage, the computational results of the ACO Algorithm were faster in finding pi values in the 5th iteration compared with PSO which got the best PI value in iteration 20th, but for the completion of harmonic distortion due to non-linear load in whole PSO algorithm is relatively better than the ACO algorithm, ACO algorithm results can reduce the value of THDI 48.88% to 3.18% and the value of THDV 20.23% to 1.48%. and for Alogaritma PSO which is slightly superior by lowering the value of THDI 48.88% to 3.11% and the value of THDV 20.23% to 1.49%.

1.
Bondarenko
S
,
Bialobrzheskyi
O
,
Todorov
O.
Power Theories Application Rationality in Series Filter-Compensating Device Control System
.
Proc 25th IEEE Int Conf Probl Autom Electr Drive Theory Pract PAEP 2020.
2020
Sep 21;
2.
Rangari
S.C.
,
Suryawanshi
H.M.
,
Shah
B.
Effect of inverter switching frequency on the stator current harmonics of five-phase induction motor
.
2017 Int Conf Energy, Commun Data Anal Soft Comput ICECDS 2017.
2018
Jun 19;
2128
32
.
3.
Lopez
J.C.
,
Cediel
O.D.F
,
Mora
J.H.
A low-cost adjustable speed drive for three-phase induction motor
.
2017 3rd IEEE Work Power Electron Power Qual Appl PEPQA 2017 - Proc.
2017
Jul 14;
4.
Wang
J
,
Pang
Y
,
Lei
D
,
Xu
Y
,
Zhang
M.
Harmonic assessments with multi-values considering the regulation effect
.
2017 2nd Int Conf Power Renew Energy, ICPRE 2017.
2018
Jun 19;
46
50
.
5.
Nayusrizal
N
,
Untari
I
,
Putra
A.A.
,
Hudaya
C.
Effects of Harmonic Distortions on the Accuracy of Energy and Power Losses Measurements in a Water Treatment Industry
.
2019 IEEE 2nd Int Conf Power Energy Appl ICPEA 2019.
2019
Apr 1;
277
81
.
6.
Torre
J.L.
,
Barros
L.A.M
,
Afonso
J.L.
,
Pinto
J.G.
Development of a Proposed Single-Phase Series Active Power Filter without External Power Sources
.
SEST 2019 - 2nd Int Conf Smart Energy Syst Technol.
2019
Sep 1;
7.
Bondarenko
S.S.
,
Bialobrzheskyi
O. V.
,
Vlasenko
R. V.
Investigation Of The Influence Of The Transformer Of A Series Active Filter On The Quality Of Voltage
.
Electr Eng Power Eng [Internet].
2018
May 31 [cited 2022 Feb 11];
0
(
1
):
93
101
. Available from: http://ee.zntu.edu.ua/article/view/133254
8.
Gowtham
N
,
Shankar
S.
PI tuning of Shunt Active Filter using GA and PSO algorithm
.
Proceeding IEEE - 2nd Int Conf Adv Electr Electron Information, Commun Bio-Informatics, IEEE - AEEICB 2016.
2016
Aug 9;
207
13
.
9.
Vanjani
H
,
Choudhury
U.K.
,
Sharma
M
,
Vanjani
B.
Takagi-sugeno (TS)-type fuzzy logic controller for three-phase four-wire shunt active power filter for an unbalanced load
.
2016 IEEE 7th Power India Int Conf PIICON 2016.
2017
Oct 19;
10.
Karuppanan
P
,
Mahapatra
K.
PID with PLL Synchronization Controlled Shunt APLC under Non-Sinusoidal and Unbalanced Conditions.
undefined.
2010
;
11.
Zahira
R
,
Fathima
A.P.
,
Muthu
R.
SPWM technique for reducing harmonics in three-phase non-linear load
.
Proc 2014 IEEE 2nd Int Conf Electr Energy Syst ICEES 2014.
2014
Oct 14;
56
60
.
12.
Kharjule
S.
Voltage source inverter
.
Int Conf Energy Syst Appl ICESA 2015.
2016
Jul 1;
537
42
.
13.
Dorigo
M
,
Maniezzo
V
,
Colorni
A.
Ant system: Optimization by a colony of cooperating agents
.
IEEE Trans Syst Man, Cybern Part B Cybern.
1996
;
26
(
1
):
29
41
.
14.
Tiwari
A.K.
,
Dubey
S.P.
Ant colony optimization-based hybrid active power filter for harmonic compensation
.
Int Conf Electr Electron Optim Tech ICEEOT 2016.
2016
Nov 22;
777
82
.
15.
Levron
Y
,
Belikov
J.
Lecture 2 : The Direct-Quadrature-Zero (DQ0) Transformation.
1
(
2
):
1
21
.
16.
Zemerov
G.G.
,
Ilyina
N.A.
,
Ilyina
O. V.
,
Sokol
E.I.
,
Tugay
D. V.
Power active filter installation effect in a three-phase four-wire distribution network
.
Int Work Tutorials Electron Devices Mater EDM - Proc.
2009
;
395
400
.
This content is only available via PDF.
You do not currently have access to this content.