Air conditioning split currently use a lot of refrigerants that are not environmentally friendly, one of which is R32. The original R32 air conditioning split was replaced with refrigerant R1270 with a cooling capacity of 1 PK. The goal of this research is to compare the performance of R1270 and R32 refrigerants. R1270 mass charged to split alternating current by 60%. The conditions of the room temperature are 23 C, 25 C, and 27 C with ambient temperature of 30 C. The room temperature conditions are 25 C and 27 C, with ambient temperature being 35 C. The cooling capacity of R1270 has decreased by 44.91% from that of R32 because the cooling capacity is lower, thus affecting the compressor's lower power consumption. There was a decrease in COP from R1270 to R32 of 12.53%. The results obtained show that the performance of the R32 is still better than the R1270.
Skip Nav Destination
Article navigation
8 May 2023
3RD BOROBUDUR INTERNATIONAL SYMPOSIUM ON SCIENCE AND TECHNOLOGY 2021
15 December 2021
Magelang, Indonesia
Research Article|
May 08 2023
Experimental study of performance AC split retrofitting R32 to R1270
Ridwan;
Ridwan
a)
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
a)Corresponding author: [email protected]
Search for other works by this author on:
Berkah Fajar;
Berkah Fajar
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
2
Undip Training Center, Energy Conversion
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
Tony Utomo;
Tony Utomo
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
Rizka Ulum
Rizka Ulum
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
a)Corresponding author: [email protected]
AIP Conf. Proc. 2706, 020087 (2023)
Citation
Ridwan, Berkah Fajar, Tony Utomo, Rizka Ulum; Experimental study of performance AC split retrofitting R32 to R1270. AIP Conf. Proc. 8 May 2023; 2706 (1): 020087. https://doi.org/10.1063/5.0120267
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
13
Views
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Social mediated crisis communication model: A solution for social media crisis?
S. N. A. Hamid, N. Ahmad, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Related Content
Experimental study of performance AC split retrofitting R32 to R290
AIP Conf. Proc. (May 2023)
Chiller performance study with refrigerant R290
AIP Conf. Proc. (January 2019)
EES analysis of low-grade thermal energy organic-rankine-vapor compression-refrigeration system
AIP Conf. Proc. (September 2023)
Sustainable building retrofits potential indicators
AIP Conference Proceedings (May 2021)
Decision-making method for building energy efficiency retrofit measures based on an improved analytic hierarchy process
J. Renewable Sustainable Energy (July 2019)