Nowadays, split air conditioners used by the public use refrigerants that are not yet environmentally friendly, one of which is refrigerant R32. The original R32 split air conditioner with a 1 PK cooling capacity was replaced with an refrigerant R290. This study aims to test the performance of refrigerant R290 compared to refrigerant R32. The mass of R290 that is charged to the split AC is 60% with an ambient temperature of 30°C at room temperatures of 23 C, 25 C, and 27 C. With another ambient temperature of 35°C at room temperatures of 25 C and 27 C. The power consumption of R290 is 35% decrease from that of R32. The cooling capacity of R290 has decreased by 33.15% from that of R32. For the COP value, R290 was a decrease 20.01% from R32. The results obtained show that the performance of the refrigerant R290 has not been maximized to replace refrigerant R32.

1.
Althouse
,
A.D.
Modern Refrigeration and Air Conditioning
;
2004
;
2.
Powell
,
R.L.
CFC phase-out: Have we met the challenge?
Journal of Fluorine Chemistry
2002
,
114
,
237
250
, doi:.
3.
Choudhari
,
C.S.
Performance Investigation of Natural Refrigerant R290 as a Substitute to R22 in Refrigeration Systems
.
Energy Procedia
2017
,
109
,
346
352
, doi:.
4.
Velders
,
G.J.M.
The large contribution of projected HFC emissions to future climate forcing
.
Proceedings of the National Academy of Sciences
2009
,
106
,
10949
10954
.
5.
UNEP
2006 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee
;
2006
;
6.
Calm
,
J.M.
;
Domanski
,
P.A.
R-22 replacement status
.
ASHRAE Journal
2004
,
46
,
29
39
.
7.
Granryd
,
E.
Hydrocarbons as refrigerants - an overview
.
International Journal of Refrigeration
2001
,
24
,
15
24
, doi:.
8.
Corberán
,
J.M.
Review of standards for the use of hydrocarbon refrigerants in A/C, heat pump and refrigeration equipment
.
International Journal of Refrigeration
2008
,
31
,
748
756
, doi:.
9.
Palm
,
B.
Hydrocarbons as refrigerants in small heat pump and refrigeration systems - A review
.
International Journal of Refrigeration
2008
,
31
,
552
563
, doi:.
10.
Berkah Fajar
,
T.K.
;
Restu Bagas
,
P.
;
Ukhi
,
S.
;
Alhamid
,
M.I.
;
Lubis
,
A.
Energy and exergy analysis of an R410A small vapor compression system retrofitted with R290
.
Case Studies in Thermal Engineering
2020
,
21
,
100671
, doi:.
11.
Tanaka
,
I.R.
;
Fajar
,
B.
;
Suryo Utomo
,
T.
;
Yohana
,
E.
;
Mustaqim Experimental Study Performance R-22 AC Split Retrofitted with Propane
.
MATEC Web of Conferences
2018
,
159
,
1
6
, doi:.
12.
Wu
,
J.H.
Experimental performance study of a small wall room air conditioner retrofitted with R290 and R1270
.
2012
, doi:.
13.
Tian
,
Q.
;
Cai
,
D.
;
Ren
,
L.
;
Tang
,
W.
;
Xie
,
Y.
;
He
,
G.
;
Liu
,
F.
An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners;
Elsevier Ltd
,
2015
; Vol.
57
; ISBN 2787540724.
14.
Lee
,
H.S.
;
Yoon
,
J.I.
;
Kim
,
J.D.
;
Bansal
,
P.K.
Condensing heat transfer and pressure drop characteristics of hydrocarbon refrigerants
.
International Journal of Heat and Mass Transfer
2006
,
49
,
1922
1927
, doi:.
15.
Lee
,
H.S.
;
Yoon
,
J.I.
;
Kim
,
J.D.
;
Bansal
,
P.K.
Characteristics of condensing and evaporating heat transfer using hydrocarbon refrigerants
.
Applied Thermal Engineering
2006
,
26
,
1054
1062
, doi:.
This content is only available via PDF.
You do not currently have access to this content.