Nowadays, split air conditioners used by the public use refrigerants that are not yet environmentally friendly, one of which is refrigerant R32. The original R32 split air conditioner with a 1 PK cooling capacity was replaced with an refrigerant R290. This study aims to test the performance of refrigerant R290 compared to refrigerant R32. The mass of R290 that is charged to the split AC is 60% with an ambient temperature of 30°C at room temperatures of 23 C, 25 C, and 27 C. With another ambient temperature of 35°C at room temperatures of 25 C and 27 C. The power consumption of R290 is 35% decrease from that of R32. The cooling capacity of R290 has decreased by 33.15% from that of R32. For the COP value, R290 was a decrease 20.01% from R32. The results obtained show that the performance of the refrigerant R290 has not been maximized to replace refrigerant R32.
Skip Nav Destination
Article navigation
8 May 2023
3RD BOROBUDUR INTERNATIONAL SYMPOSIUM ON SCIENCE AND TECHNOLOGY 2021
15 December 2021
Magelang, Indonesia
Research Article|
May 08 2023
Experimental study of performance AC split retrofitting R32 to R290
Rizka Ulum;
Rizka Ulum
a)
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
a)Corresponding author: rizkanoormu27@gmail.com
Search for other works by this author on:
Berkah Fajar;
Berkah Fajar
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
2
Undip Training Center, Energy Conversion
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
Tony Suryo Utomo;
Tony Suryo Utomo
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
Ridwan
Ridwan
1
Department of Mechanical Engineering, Diponegoro University
, Semarang, 50249, Central Java, Indonesia
Search for other works by this author on:
a)Corresponding author: rizkanoormu27@gmail.com
AIP Conf. Proc. 2706, 020086 (2023)
Citation
Rizka Ulum, Berkah Fajar, Tony Suryo Utomo, Ridwan; Experimental study of performance AC split retrofitting R32 to R290. AIP Conf. Proc. 8 May 2023; 2706 (1): 020086. https://doi.org/10.1063/5.0120263
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
16
Views
Citing articles via
Social mediated crisis communication model: A solution for social media crisis?
S. N. A. Hamid, N. Ahmad, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Related Content
Experimental study of small wall room air conditioner for R-22 retrofitted with R290 95.5%
AIP Conf. Proc. (January 2019)
Chiller performance study with refrigerant R290
AIP Conf. Proc. (January 2019)
Experimental study of performance AC split retrofitting R32 to R1270
AIP Conf. Proc. (May 2023)
Effects of sub-cooler on cooling performance of air conditioning system with natural refrigerant R290
AIP Conf. Proc. (November 2020)