Jakarta International Stadium is a multi-function stadium which has a building area of 222,940 m2 consisting of nine floors and can accommodate 82,000 spectators. In this study, the optimization level of the power flow (load flow) with the Newton Raphson method will be seen and calculate the short circuit current referring to the IEC International Electrotechnical Commission (IEC) standard, namely IEC 60909.1 to IEC 60909.4 standards. Optimization is done by adding a 300 kVAR Capacitor Bank and tapping a 2% transformer on the west side panel and adding a 480kVAR capacitor bank and 2.5% tapping transformer on the east side panel. The optimization results resulted in a decrease in current at a voltage of 20 kV from 193.9 Ampere to 173.3 Ampere or a decrease of 20.6 Ampere, this decrease reached 10.62%.

1.
A.
Tanjung
, “
Reconfiguration of Power Supply System Distribution 20 Kv: PT. PLN (Persero) Dumai Area Case
,”
IOP Conf. Ser. Earth Environ. Sci.
, vol.
175
, no.
1
,
2018
, doi: .
2.
A. M.
Eltamaly
,
A. N. A.
Elghaffar
, and
A.
Ahmed
, “
Optimum Power Flow Analysis By Newton Raphson
,”
Ann. Fac. Eng. Hunedoara – Int. J. Eng. Tome XVI [2018]
, no. December,
2018
.
3.
S. S.
Shrawane
 et al., “
Simulation and Load Flow Analysis of Interconection System
,”
J. Ilm. Giga
, vol.
8
, no.
1
, pp.
114
121
,
2018
, doi: .
4.
M.
Fikri
and
D.
Anggaini
, “
Metode Newton Raphson Untuk Analisis Aliran Daya Jaringan
,”
J. Ilm. SUTET
, vol.
8
, no.
2
, pp.
114
121
,
2018
.
5.
Hariyadi
, “
ISSN 2599-2081 EISSN 2599-2090 Fak. Teknik UMSB Rang Teknik Journal
,”
Vol. I No.1 Januari 2018
, vol.
I
, no.
1
, pp.
43
51
,
2018
.
6.
R.
Ruliyanto
, “
Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral dan Arus Ground pada Trafo 1 dan Trafo 2 pada Beban Puncak Sesaat
,”
J. Ilm. Giga
, vol.
23
, no.
1
, p.
27
,
2020
, doi: .
7.
D.
Sulistiyono
, “
Perbandingan metode gauss - seidel, metode newton raphson dan metode fast decoupled dalam solusi aliran daya
,”
Makal. Tugas Akhir
,
2011
.
8.
A.
Supriyadi
, “
Analisa Aliran Daya Pada Sistem Tenaga Listrik Menggunakan Software Etap 12.6
,”
FORUM Teknol.
, vol.
06
, no.
3
,
2018
.
9.
H. D.
Laksono
, “
Perbandingan Metoda Newton Raphson Dan Metoda Fast Decouple Pada Studi Aliran Daya (Aplikasi PT. PLN Sumbar-Riau 150 KV
),”
Univ. Andalas
, vol.
3
, no.
27
, pp.
1
10
,
2014
.
10.
L.
Wang
,
C.
Chen
, and
T.
Shen
, “
Improvement of power flow calculation with optimization factor based on current injection method
,”
Discret. Dyn. Nat. Soc.
, vol.
2014
,
2014
, doi: .
11.
I.
Handayani
, “
Analisis Aliran Daya Dan Gangguan Hubung Singkat Sistem Kelistrikan Pabrik Tonasa V Di Pt Semen Tonasa Menggunakan Etap
,”
Jur. Tek. Fak. Tek. Univ. Hasanuddin
, pp.
8
138
,
2012
.
This content is only available via PDF.
You do not currently have access to this content.