Jakarta International Stadium is a multi-function stadium which has a building area of 222,940 m2 consisting of nine floors and can accommodate 82,000 spectators. In this study, the optimization level of the power flow (load flow) with the Newton Raphson method will be seen and calculate the short circuit current referring to the IEC International Electrotechnical Commission (IEC) standard, namely IEC 60909.1 to IEC 60909.4 standards. Optimization is done by adding a 300 kVAR Capacitor Bank and tapping a 2% transformer on the west side panel and adding a 480kVAR capacitor bank and 2.5% tapping transformer on the east side panel. The optimization results resulted in a decrease in current at a voltage of 20 kV from 193.9 Ampere to 173.3 Ampere or a decrease of 20.6 Ampere, this decrease reached 10.62%.
Skip Nav Destination
,
,
,
Article navigation
10 November 2022
PROCEEDING OF THE 1ST INTERNATIONAL CONFERENCE ON STANDARDIZATION AND METROLOGY (ICONSTAM) 2021
20 October 2021
Tangerang Selatan, Indonesia
Research Article|
November 10 2022
Optimization of electric load flow at Jakarta International Stadium with Newton Raphson method
Ruliyanta Ruliyanta;
Ruliyanta Ruliyanta
a)
1
Fakulty of Engineering and Science, National University
, South Jakarta, Indonesia
2
Student at Faculty of Electronic Engineering and Computer Engineering, Universiti Teknikal Malaysia Melaka (UTeM)
, Malaka, Malaysia
a)Corresponding author: [email protected]
Search for other works by this author on:
Adhyartha Keraf;
Adhyartha Keraf
b)
1
Fakulty of Engineering and Science, National University
, South Jakarta, Indonesia
Search for other works by this author on:
Endang Retno Nugroho;
Endang Retno Nugroho
c)
1
Fakulty of Engineering and Science, National University
, South Jakarta, Indonesia
Search for other works by this author on:
Seprita Amanda
Seprita Amanda
d)
1
Fakulty of Engineering and Science, National University
, South Jakarta, Indonesia
Search for other works by this author on:
Ruliyanta Ruliyanta
1,2,a)
Adhyartha Keraf
1,b)
Endang Retno Nugroho
1,c)
Seprita Amanda
1,d)
1
Fakulty of Engineering and Science, National University
, South Jakarta, Indonesia
2
Student at Faculty of Electronic Engineering and Computer Engineering, Universiti Teknikal Malaysia Melaka (UTeM)
, Malaka, Malaysia
a)Corresponding author: [email protected]
AIP Conf. Proc. 2664, 050004 (2022)
Citation
Ruliyanta Ruliyanta, Adhyartha Keraf, Endang Retno Nugroho, Seprita Amanda; Optimization of electric load flow at Jakarta International Stadium with Newton Raphson method. AIP Conf. Proc. 10 November 2022; 2664 (1): 050004. https://doi.org/10.1063/5.0108155
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
38
Views
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Related Content
Exploring equations ordering influence on variants of the Newton-Raphson method
AIP Conf. Proc. (October 2016)
Solar cell parameters estimation from illuminated I-V characteristic using linear slope equations and Newton-Raphson technique
J. Renewable Sustainable Energy (May 2013)
Mathematical modelling of the distribution network for three-phase power flow analysis
AIP Conf. Proc. (September 2023)
Modified Newton-Raphson GRAPE methods for optimal control of spin systems
J. Chem. Phys. (May 2016)
Performance analysis of SHE-PWM using Fourier Series and Newton-Raphson analysis
AIP Conf. Proc. (May 2015)