Water is a natural resource and plays an important role in human life to be consumed. Water used for consumption should be clean, colorless, tasteless, odorless according the Indonesia Ministry of Health standards. The water quality test measures parameters such as pH, total dissolve solid (TDS), and water temperature based on IoT and Arduino as a microcontroller. The design of Water Quality Device Test is carried out using the value and trust design method. To solve these challenges, we propose a value-oriented reference process for innovative functionalities of a Water Quality Device Test. We have found that the consideration of the human values involved is of great importance for the identification of stakeholders throughout the development process. The results show that the comparison between laboratory test results versus Water Quality Device Test. The quality test comes from 10 depots. Based on the results of the paired sample t-test, it is known that the t-statistic or t-value for pH, TDS and drinking water temperature values shows lower value (<) than the t-table value (1.81246). These means that the pH, TDS, and temperature values of drinking water do not show differences in results when tested in the laboratory and using Water Quality Device Test.

1.
F.
Amani
and
K.
Prawiroredjo
,
J. JETRi
,
14
,
49
62
(
2016
).
2.
J.
Renngiwur
,
J. Biol. Sci. Educ.
,
5
,
2
,
101
(
2016
).
3.
A.
Mashadi
,
B.
Surendro
,
A.
Rakhmawati
, and
M.
Amin
,
J. Ris. Rekayasa Sipil
,
1
,
2
,
105
(
2018
).
4.
Hasrianti
and
Nurasia
,
J. Kesehat. Lingkung. Indones.
,
2
,
1
,
747
753
(
2016
).
5.
T.
Indrawan
,
Maj. Geogr. Indones.
26
,
1
,
46
59
(
2016
).
6.
S.
Yudo
and
P. N.
Rahardjo
,
J. Air Indones.
,
1
,
3
(
2018
).
7.
S.
Fordyce
,
Des. Cult.
,
12
,
1
,
109
111
(
2020
).
8.
I.
van de Poel
,
L.
Asveld
,
S.
Flipse
,
P.
Klaassen
,
V.
Scholten
, and
E.
Yaghmaei
,
Sustain.
,
9
,
11
,
1
18
(
2017
).
9.
R.
Graubohm
,
T.
Schräder
, and
M.
Maurer
,
Proc. Des. Soc. Des.
1
,
907
916
(
2020
).
10.
D. D.
Koo
,
J. J.
Lee
,
A.
Sebastiani
, and
J.
Kim
,
Procedia Eng.
145
,
396
403
(
2016
).
11.
B.
Knowles
. “
Models and patterns of trust
” (
CSCW Proceeding
,
2015
) pp.
328
338
.
12.
S.
Kumar
,
P.
Tiwari
, and
M.
Zymbler
,
J. Big Data
,
6
,
1
(
2019
).
13.
N. B.
Truong
,
H.
Lee
,
B.
Askwith
, and
G. M.
Lee
,
Sensors
,
17
,
6
,
1
24
(
2017
).
14.
Y. E.
Putra
,
S. R.
Sulistiyanti
, and
M.
Komarudin
,
Electrician
,
12
,
3
,
84
(
2018
).
15.
A. D. O.
Hidayat
,
S.
Oyama
, and
A.
Riyadi
, “
Pengamatan pH Air Seni Berbasis IoT Menggunakan Arduino Uno untuk Mendeteksi Penyakit Diabetes
,” (
Prosiding Seminar
,
2020
) pp.
43
45
.
16.
H.
Hassani
and
E. S.
Silva
,
3
,
3
,
590
609
(
2015
).
17.
F.
Melinda
,
S.
Laili
, and
A.
Syauqi
,
Biosaintropis
,
3
,
1
,
53
59
(
2017
).
18.
A. S.
Raksanagara
,
S.
Fitriyah
,
I.
Afriadi
, and
H.
Sukandar
, “Internal and External Aspects Related to Quality of Refill Water Station Production: Qualitative Study in Bandung City” (
Majalah. Kedoktoram
.
Bandung
,
2018
).
This content is only available via PDF.
You do not currently have access to this content.