The heart is a primary organ inside the human body. Therefore, it is necessary to take care of their health. One way to find out his health is by monitoring the heart itself. In monitoring the heart, it is very necessary to store monitoring results to facilitate the medical team or doctors in conducting patient examinations. Therefore, a research was conducted to design or create a heart signal data logger system as a modification of an electrocardiograph commonly known as a holter monitor. From the results of measuring the amplitude of the R wave height on the holter monitor and the original ECG with phantom input, the average relative error is 3.67% and the length of the R to R distance is -23.8%. Then from the results of measuring the amplitude of the R wave height on the Holter monitor and the original ECG with the same input from the same patient in four different positions. The lying position has a relative error value of -73,3%, sitting position -53.8%, standing position -45.2%, and walking position -56.6%. Whilst, for the length of the distance from R to R, the lying position has a relative error value of 10.3%, the sitting position is 33.3%, the standing position is -10%, and the walking position is 29.4%.
Skip Nav Destination
Article navigation
30 November 2022
2021 2ND INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, ADVANCED MECHANICAL AND ELECTRICAL ENGINEERING (ICITAMEE)
25–26 August 2021
Yogyakarta, Indonesia
Research Article|
November 30 2022
One lead data logger system on heart signal
Erika Loniza;
Erika Loniza
a)
1
Departement of Medical Electronics Technology, Universitas Muhammadiyah Yogyakarta
, Brawijaya Street, Kasihan, Bantul Yogyakarta 55183 Indonesia
a)Corresponding author: [email protected]
Search for other works by this author on:
Ahmad Helmy Wahyudin;
Ahmad Helmy Wahyudin
b)
1
Departement of Medical Electronics Technology, Universitas Muhammadiyah Yogyakarta
, Brawijaya Street, Kasihan, Bantul Yogyakarta 55183 Indonesia
Search for other works by this author on:
Wisnu Kartika
Wisnu Kartika
c)
1
Departement of Medical Electronics Technology, Universitas Muhammadiyah Yogyakarta
, Brawijaya Street, Kasihan, Bantul Yogyakarta 55183 Indonesia
Search for other works by this author on:
AIP Conf. Proc. 2499, 080005 (2022)
Citation
Erika Loniza, Ahmad Helmy Wahyudin, Wisnu Kartika; One lead data logger system on heart signal. AIP Conf. Proc. 30 November 2022; 2499 (1): 080005. https://doi.org/10.1063/5.0105109
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
19
Views
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Social mediated crisis communication model: A solution for social media crisis?
S. N. A. Hamid, N. Ahmad, et al.
Recognition of cat ras of face and body using convolutional neural networks
Akhmad Wahyu Aji, Esmeralda Contessa Djamal, et al.
Related Content
The Seven-Segment Data Logger
Phys. Teach. (December 2015)
Methods for accurate cold-chain temperature monitoring using digital data-logger thermometers
AIP Conference Proceedings (September 2013)
Design a data logger to record the working time of the lathe in the implementation of preventive maintenance
AIP Conference Proceedings (June 2022)
Water bath 8-channel calibrator using Android application as a test parameter interface and data storage system
AIP Conf. Proc. (October 2024)
Design of an accurate wireless data logger for vibration analysis with Android interface
Rev. Sci. Instrum. (December 2016)