The heart is a primary organ inside the human body. Therefore, it is necessary to take care of their health. One way to find out his health is by monitoring the heart itself. In monitoring the heart, it is very necessary to store monitoring results to facilitate the medical team or doctors in conducting patient examinations. Therefore, a research was conducted to design or create a heart signal data logger system as a modification of an electrocardiograph commonly known as a holter monitor. From the results of measuring the amplitude of the R wave height on the holter monitor and the original ECG with phantom input, the average relative error is 3.67% and the length of the R to R distance is -23.8%. Then from the results of measuring the amplitude of the R wave height on the Holter monitor and the original ECG with the same input from the same patient in four different positions. The lying position has a relative error value of -73,3%, sitting position -53.8%, standing position -45.2%, and walking position -56.6%. Whilst, for the length of the distance from R to R, the lying position has a relative error value of 10.3%, the sitting position is 33.3%, the standing position is -10%, and the walking position is 29.4%.

1.
A. C.
Stephenson
,
R.
Willis
, and
C.
Alford
, “
Using in-seat electrical potential sensors for non-contact monitoring of heart rate, heart rate variability, and heart rate recovery
,”
International Journal of Psychophysiology
, vol.
169
, no. April, pp.
1
10
,
2021
, doi: .
2.
S. S.
Ponnusamy
and
P.
Vijayaraman
, “
Electrocardiography guided left bundle branch pacing
,”
Journal of Electrocardiology
, vol.
68
, pp.
11
13
,
2021, doi
: .
3.
B.
Babusiak
,
M.
Gala
, and
S.
Borik
,
“Hardware Design of ECG Data Logger,” in
10th International Conference
,
2014
, pp.
514
517
. doi: .
4.
C. C.
Ji
 et al., “
The Role of Holter Monitoring in the Diagnosis of Early Repolarisation Pattern
,”
Heart Lung and Circulation
, vol.
27
, no.
12
, pp.
1421
1427
,
2018, doi
: .
5.
H. L.
Kennedy
, “
The evolution of Ambulatory ECG Monitoring
,”
Progress in Cardiovascular Diseases
, vol.
56
, no.
2
, pp.
127
132
,
2013
, doi: .
6.
T.
Hendrikx
,
M.
Rosenqvist
,
P.
Wester
,
H.
Sandström
, and
R.
Hörnsten
, “
Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias
,”
BMC Cardiovascular Disorders
, vol.
14
, pp.
1
8
,
2014
, doi: .
7.
A.
Dhillon
,
P.
Anderson
,
J.
Holmes-Walker
,
T.
Deshmukh
, and
J.
Chong
, “
24-Hour Holter Monitor Assessment of Heart Rate Variability Across the Spectrum of Diabetes
,”
Heart, Lung and Circulation
, vol.
27
, pp.
S291
S292
,
2018, doi
: .
8.
M.
Bolourchi
,
E. S.
Silver
,
D.
Muwanga
,
E.
Mendez
, and
L.
Liberman
, “
Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children
,”
American Journal of Cardiology
, vol.
125
, no.
5
, pp.
767
771
,
2020
, doi: .
9.
H. L.
Kennedy
, “
The evolution of Ambulatory ECG Monitoring
,”
Progress in Cardiovascular Diseases
, vol.
56
, no.
2
, pp.
127
132
,
2013, doi
: .
10.
M.
Karlsson
,
R.
Hörnsten
,
A.
Rydberg
, and
U.
Wiklund
, “
Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: A comparison with carefully edited data
,”
BioMedical Engineering Online
, vol.
11
, pp.
1
12
,
2012
, doi: .
11.
S. Briongos
Figuero
,
Á.
Estévez Paniagua
,
A. Sánchez
Hernández
,
A.
Abad-Motos
,
A.
Ruiz
, and
R.
Muñoz-Aguilera
, “
Leadless atrioventricular synchronous pacing: a validation pilot study with Holter monitoring
,”
Revista Española de Cardiología (English Edition)
, no. x, pp.
2
3
,
2021, doi
: .
12.
Z.
Guo
,
Y.
Huang
, and
L.
Li
, “
Research and design preamplifier circuit of atmospheric electric field meter
,”
2011 7th Asia-Pacific International Conference on Lightning, APL2011
, pp.
504
507
,
2011
, doi: .
This content is only available via PDF.