The effect of agarose gel coating on tapered fiber ability to detect relative humidity changes was studied here. Agarose gel is a hydrophilic material commonly used for relative humidity sensing. Tapered fiber makes a good choice for sensing structure due to evanescent mode interaction with the external surroundings. Two different types of tapered fiber were studied, plastic and silica, each type was used to construct a separate sensing structure. In the relative humidity range of 50-80%RH, agarose coated silica tapered fiber showed a sensitivity of 0.1054dB/%RH compared to the 0.0106 dB/RH% sensitivity of the uncoated silica fiber. On the other hand, tapered plastic fiber coated with agarose showed a sensitivity of 0.0228mV/%RH compared to the uncoated plastic fiber sensitivity of 0.0028mV/RH%. This shows agarose’s potential as a coating for fiber optics relative humidity sensors.

1.
Y.
Peng
,
Y.
Zhao
,
M. Q.
Chen
, and
F.
Xia
, “
Research Advances in Microfiber Humidity Sensors
,”
Small
, vol.
14
, no.
29
, pp.
1
20
,
2018
.
2.
T. L.
Yeo
,
T.
Sun
, and
K. T. V
Grattan
, “
Fibre-optic sensor technologies for humidity and moisture measurement,
” vol.
144
, pp.
280
295
,
2008
.
3.
A.
Kapic
,
A.
Tsirou
,
P. G.
Verdini
, and
S.
Carrara
, “
Humidity Sensors for High Energy Physics Applications: A Review
,”
IEEE Sens. J.
, vol.
20
, no.
18
, pp.
10335
10344
,
2020
.
4.
J.
Lou
,
Y.
Wang
,
L.
Tong
,
J.
Lou
,
Y.
Wang
, and
L.
Tong
, “
Microfiber Optical Sensors: A Review
,”
Sensors
, vol.
14
, no.
4
, pp.
5823
5844
, Mar.
2014
.
5.
H. E.
Joe
,
H.
Yun
,
S. H.
Jo
,
M. B. G.
Jun
, and
B. K.
Min
, “
A review on optical fiber sensors for environmental monitoring
,”
Int. J. Precis. Eng. Manuf. - Green Technol.
, vol.
5
, no.
1
, pp.
173
191
,
2018
.
6.
J.
Ignacio
R.
Matias
,
Satoshi
Ikezawa
,
Fiber Optic Sensors: Current Status and Future Possibilities
, vol.
21
.
2017
.
7.
T. A.
Blank
,
L. P.
Eksperiandova
, and
K. N.
Belikov
, “
Recent trends of ceramic humidity sensors development: A review
,”
Sensors Actuators, B Chem
., vol.
228
, pp.
416
442
,
2016
.
8.
A.
Hale
,
D. J.
DiGiovanni
,
J. M.
Fini
,
M.
Sumetsky
, and
Y.
Dulashko
, “
The Microfiber Loop Resonator: Theory, Experiment, and Application
,”
J. Light. Technol.
Vol.
24
, Issue
1
, pp.
242
-, vol. 24, no. 1, p. 242, Jan.
2006
.
9.
H. Adnan
Zain
et al, “
ZnO nanorods coated microfiber loop resonator for relative humidity sensing
,”
Opt. Fiber Technol
., vol.
54
, no. August 2019,
2020
.
10.
J. C.
Shin
,
M. S.
Yoon
, and
Y. G.
Han
, “
Relative humidity sensor based on an optical microfiber knot resonator with a polyvinyl alcohol overlay
,”
J. Light. Technol.
, vol.
34
, no.
19
, pp.
4511
4515
, Oct.
2016
.
11.
C.-B.
Yu
et al, “
Graphene oxide deposited microfiber knot resonator for gas sensing
,”
Opt. Mater. Express
, vol.
6
, no.
3
, p.
727
,
2016
.
12.
G. E. F.
Arrell
and
Y. U. S.
Emenova
, “
Agarose coated spherical micro resonator for humidity measurements
,” vol.
24
, no.
19
, pp.
77
83
,
2016
.
13.
M. A.
Butt
,
S. N.
Khonina
, and
N. L.
Kazanskiy
, “
A serially cascaded micro-ring resonator for simultaneous detection of multiple analytes
,”
Laser Phys.
, vol.
29
, no.
4
, pp.
0
6
,
2019
.
14.
L.
Cai
,
J.
Pan
,
Y.
Zhao
,
J.
Wang
, and
S.
Xiao
, “
Whispering Gallery Mode Optical Microresonators: Structures and Sensing Applications
,”
Phys. Status Solidi Appl. Mater. Sci
., vol.
217
, no.
6
,
2020
.
15.
S.
Qiao
, “
Humidity Sensor Based on Fiber Grating Coated with Graphene Oxide,”
J. Phys. Conf. Ser.
, vol.
1213
, no.
4
,
2019
.
16.
M.
Shao
et al, “
Humidity sensing of microfiber Bragg grating,” 2015
, vol.
9449
, p.
944916
.
17.
S. W.
Harun
,
K. S.
Lim
,
C. K.
Tio
,
K.
Dimyati
, and
H.
Ahmad
, “
Theoretical analysis and fabrication of tapered fiber
,”
Optik (Stuttg)
., vol.
124
, no.
6
, pp.
538
543
,
2013
.
18.
M.
Pospíšilová
,
G.
Kuncová
, and
J.
Trögl
, “
Fiber-optic chemical sensors and fiber-optic bio-sensors
,”
Sensors (Switzerland)
, vol.
15
, no.
10
, pp.
25208
25259
,
2015
.
19.
J. M.
Corres
,
F. J.
Arregui
, and
I. R.
Matias
, “
Design of humidity sensors based on tapered optical fibers
,”
J. Light. Technol.
, vol.
24
, no.
11
, pp.
4329
4336
,
2006
.
20.
H. H. M.
Yusof
,
H. R. A.
Rahim
,
S.
Thokchom
,
K.
Dimyati
, and
S. W.
Harun
, “
Uric acid sensing using tapered silica optical fiber coated with zinc oxide nanorods
,”
Microw. Opt. Technol. Lett.
, vol.
60
, no.
3
, pp.
645
650
,
2018
.
21.
L.
Zhang
,
F.
Gu
,
J.
Lou
,
X.
Yin
, and
L.
Tong
, “
Fast detection of humidity with a subwavelength-diameter fiber taper coated with gelatin film
,”
Opt. Express
, vol.
16
, no.
17
, p.
13349
,
2008
.
22.
M.
Batumalay
,
A.
Lokman
,
F.
Ahmad
,
H.
Arof
,
H.
Ahmad
, and
S. W.
Harun
, “
Tapered plastic optical fiber coated with HEC/PVDF for measurement of relative humidity
,”
IEEE Sens. J.
, vol.
13
, no.
12
, pp.
4702
4705
,
2013
.
23.
Z.
Harith
et al, “
Relative humidity sensor employing optical fibers coated with ZnO nanostructures
,”
Indian J. Sci. Technol.
, vol.
8
, no.
35
, pp.
1
5
,
2015
.
24.
A. K.
Mallik
,
D.
Liu
,
V.
Kavungal
,
Q.
Wu
,
G.
Farrell
, and
Y.
Semenova
, “
Agarose coated spherical micro resonator for humidity measurements
,”
Opt. Express
, vol.
24
, no.
19
, p.
21216
,
2016
.
25.
A. K.
Mallik
,
G.
Farrell
,
D.
Liu
,
V.
Kavungal
,
Q.
Wu
, and
Y.
Semenova
, “
A Coated Spherical Microresonator for Measurement of Water Vapor Concentration at PPM Levels in Very Low Humidity Environments
,”
J. Light. Technol.
, vol.
36
, no.
13
, pp.
2667
2674
,
2018
.
26.
N.
Irawati
et al, “
Relative Humidity Sensing Using a PMMA Doped Agarose Gel Microfiber
,”
J. Light. Technol.
, vol.
35
, no.
18
, pp.
3940
3944
,
2017
.
27.
M.
Batumalay
,
S. W.
Harun
,
F.
Ahmad
,
R. M.
Nor
,
N. R.
Zulkepely
, and
H.
Ahmad
, “
Study of a fiber optic humidity sensor based on agarose gel
,”
J. Mod. Opt.
, vol.
61
, no.
3
, pp.
244
248
, Feb.
2014
.
This content is only available via PDF.
You do not currently have access to this content.