Power quality is one issue that worries the entire power system. Increased use of modern load devices and factor like power system parameters reduce the quality of power. Active power filter (APF) is a custom power device used to reduce the harmonic distortion and increase the power quality in power system. Control of APF is the main course of action in compensating the harmonics in power system. This paper presents the Active power filter (APF), controlled with SRF and IRP theories for the compensation of harmonics. Source current and load current distortion analysis is presented. Analysis is presented and the model is developed using MATLAB/SIMULINK software.

1.
Marcos
Sacasqui
,
Jaime
Luyo
,
Alexi
Delgado
, "A Unified Index for Power Quality Assessment in Distributed Generation Systems Using Grey Clustering and Entropy Weight",
ANDESCON
2018
IEEE
, pp.
1
4
,
2018
.
2.
M.
Panoiu
,
C.
Panoiu
and
L.
Ghiormez
, "
Neuro-fuzzy modeling and prediction of current total harmonic distortion for high power nonlinear loads
,"
2018 Innovations in Intelligent Systems and Applications (INISTA
),
Thessaloniki
,
2018
, pp.
1
7
.
3.
B.
Singh
,
M.
Kandpal
and
I.
Hussain
, "
Control of Grid Tied Smart PV-DSTATCOM System Using an Adaptive Technique
," in
IEEE Transactions on Smart Grid
, vol.
9
, no.
5
, pp.
3986
3993
, Sept.
2018
4.
G. Deep
Srivastava
and
R. D.
Kulkarni
, "
Design, simulation and analysis of Shunt Active Power Filter using instantaneous reactive power topology
,"
2017 International Conference on Nascent Technologies in Engineering (ICNTE
),
Navi Mumbai
,
2017
, pp.
1
6
.
5.
J.
Meyer
,
A.
Blanco
,
S.
Rönnberg
,
M.
Bollen
and
J.
Smith
, "
CIGRE C4/C6.29: survey of utilities experiences on power quality issues related to solar power
," in
CIRED - Open Access Proceedings Journal
, vol.
2017
, no.
1
, pp.
539
543
, 10
2017
.
6.
R.
Guzman
L. G.
De Vicuña
J.
Morales
M.
Castilla
J.
Miret
"
Model-based control for a three-phase shunt active power filter
"
IEEE Trans. Ind. Electron.
vol.
63
no.
7
pp.
3998
4007
July
2016
.
7.
J. Rodriguez
Maldonado
, "
Total Harmonic Distortion Estimation, Minimization Inter Harmonic Amplitude and Expanding Bands Rejection in TKF filters
," in
IEEE Latin America Transactions
, vol.
14
, no.
2
, pp.
652
656
, Feb.
2016
.
8.
D.
Suresh
,
D. M.
Rao
and
G. D.
Sukumar
, "
Reduced rating hybrid DSTATCOM for three phase four wire distribution system
,"
2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES
),
Delhi
,
2016
, pp.
1
4
.
9.
M. A.
Chitsazan
and
A. M.
Trzynadlowski
, "
Harmonic mitigation in interphase power controller using passive filter-based phase shifting transformer
,"
2016 IEEE Energy Conversion Congress and Exposition (ECCE
),
Milwaukee, WI
,
2016
, pp.
1
5
10.
R. R.
Chilipi
,
B.
Singh
and
S. S.
Murthy
, "
Performance of a Self-Excited Induction Generator With DSTATCOM-DTC Drive-Based Voltage and Frequency Controller
," in
IEEE Transactions on Energy Conversion
, vol.
29
, no.
3
, pp.
545
557
, Sept.
2014
.
This content is only available via PDF.
You do not currently have access to this content.