This study assessed the physical and chemical parameters related to indoor air quality (IAQ) at Universiti Tenaga Nasional (UNITEN) and the IAQ of selected campus buildings were compared with guidelines provided by DOSH. This study is especially important as students spend most of their time indoors thus making them more vulnerable to exposure to indoor contaminants. Seven sampling locations around the UNITEN campus were selected which all have different layout. The method of data collection is based on Industry Code of Practice on Indoor Air Quality 2010 (ICOP). The indoor contaminants were recorded using real-time monitoring method and the parameters of interest are the Particulate Matter (PM2.5 and PM10), Total Volatile Organic Compound (TVOC), relative humidity and temperature. Results show that the parameters of IAQ level in UNITEN is at a safe level as it is well below the DOSH permissible limit. One-way ANOVA analysis was used to identify whether or not the mean of the IAQ parameters specifically PM2.5, PM10 and TVOC are the same and belongs to the same population. Statistical analysis also shows that there was no significant difference in IAQ level between all sampling locations (P≤0.05).
Skip Nav Destination
Article navigation
21 July 2021
PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS ENGINEERING & TECHNOLOGY (ICAMET 2020)
26–27 November 2020
Langkawi, Malaysia
Research Article|
July 21 2021
Study of indoor air quality (IAQ) using one-way Anova
M. I. S. M. Anuar;
M. I. S. M. Anuar
a)
1
Department of Civil Engineering, Universiti Tenaga Nasional
, Kampus Putrajaya, 43000, Kajang, Selangor, Malaysia
a)Corresponding author: [email protected]
Search for other works by this author on:
N. H. Mardi;
N. H. Mardi
b)
1
Department of Civil Engineering, Universiti Tenaga Nasional
, Kampus Putrajaya, 43000, Kajang, Selangor, Malaysia
Search for other works by this author on:
N. Zaini;
N. Zaini
c)
1
Department of Civil Engineering, Universiti Tenaga Nasional
, Kampus Putrajaya, 43000, Kajang, Selangor, Malaysia
Search for other works by this author on:
N. M. Zahari
N. M. Zahari
d)
1
Department of Civil Engineering, Universiti Tenaga Nasional
, Kampus Putrajaya, 43000, Kajang, Selangor, Malaysia
Search for other works by this author on:
a)Corresponding author: [email protected]
AIP Conf. Proc. 2347, 020142 (2021)
Citation
M. I. S. M. Anuar, N. H. Mardi, N. Zaini, N. M. Zahari; Study of indoor air quality (IAQ) using one-way Anova. AIP Conf. Proc. 21 July 2021; 2347 (1): 020142. https://doi.org/10.1063/5.0051558
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
59
Views
Citing articles via
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Students’ mathematical conceptual understanding: What happens to proficient students?
Dian Putri Novita Ningrum, Budi Usodo, et al.
Related Content
Estimation of air quality index in Madurai city
AIP Conf. Proc. (July 2024)
IOT based environment harmful gases detecting and controlling system
AIP Conference Proceedings (May 2022)
Using observation and prediction to identify traffic air emission impact on surrounding residential areas in Najaf, Iraq
AIP Conf. Proc. (October 2024)
Occupational vibration exposure monitoring practices in manufacturing industries in Shah Alam, Selangor
AIP Conf. Proc. (November 2023)
Progress of teaching and learning of nuclear engineering courses at College of Engineering, Universiti Tenaga Nasional (UNITEN)
AIP Conference Proceedings (April 2015)