The paper is focused on experimental study of the residual behavior of concrete beams reinforced with glass fiber reinforced polymer (GFRP), carbon fiber reinforced polymer (CFRP) and steel rebars after high temperature exposure equivalent to fire load. The four-point bending test was carried out on the beams after cooling. Beside load-bearing capacity, deflection of the beams is also presented in this study.
REFERENCES
1.
H.
Hajiloo
, M. F.
Green
, J.
Gales
, “Mechanical properties of GFRP reinforcing bars at high temperatures
” in Construction and Building Materials.
162
, 2018
, pp.142
–154
. DOI: .2.
H.
Blontrock
, L.
Taerwe
, S.
Matthys
, “Properties of fiber reinforced plastics at elevated temperatures with regards to fire resistance of reinforced concrete members
” in Fourth International Symposium on Non- Metallic (FRP) Reinforcement for Concrete Structures.
188
, 1999
, 43
–54
.3.
M.
Saafi
, „Effect of fire on FRP reinforced concrete members
” in Composite Structures.
58
, 2002
, pp 11
–20
.4.
R.
Hamad
, J.
Megat
, A.
Megat
, R.
Haddad
, “Mechanical properties and bond characteristics of different fiber reinforced polymer rebars at elevated temperatures
” in Construction and Building Materials.
142
, 2017
, pp. 521
–535
. DOI: .5.
Y. C.
Wang
, V.
Kodur
, “Variation of strength and stiffness of fibre reinforced polymer reinforcing bars with temperature
” in Cement and Concrete Composites
, 27
, 2005
.6.
Standard CSA S806-12
, „Design and Construction of Building Structures with Fibre-Reinforced Polymers
”, Canadian Standards Association
, 2012
.7.
D.
Ellis
, H.
Tabatabai
, A.
Nabizadeh
, “Residual Tensile Strength and Bond Properties of GFRP Bars after Exposure to Elevated Temperatures
” in Materials.
11
(3
), 2018
, DOI: .8.
A.
Abbasi
, P. J.
Hogg
, “Fire testing of concrete beams with fibre reinforced plastic rebar
” in Composites Part A: Applied Science and Manufacturing.
35
, 2006
, pp 1142
–1150
. DOI: .9.
Standard ČSN EN 12390-3
, “Testing hardened concrete - Part 3: Compressive strength of test specimens
". Czech office for standards, metrology and testing
, 2020
.10.
Standard ČSN EN 12390-5
, “Testing hardened concrete- Part 5: Flexural strength of test specimens
". Czech office for standards, metrology and testing
, 2019
.11.
Standard EN 1991-1-1
, „Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self- weight, imposed loads for buildings“. CEN, 2002
.12.
Fib
, „Bulletin 40: FRP reinforcement in RC structures
”. International Federation for Structural Concrete
, 2007
.13.
F.
Girgle
, P.
Štěpánek
, D.
Horák
, P.
Daněk
, V.
Kostiha
, "Newly developed anchoring element for prestressed FRP reinforcement – functionality and design
” in FRPRCS-11: proceedings: 11th International Symposium on Fiber Reinforced Polymer for Reinforced Concrete Structures
, 2013
.14.
P.
Daněk
, I.
Rozsypalová
, O.
Karel
, “Experimental study of concrete beams reinforced with GFRP rebars exposed to high temperatures
” in Key Engineering Materials
, 808
, 2019
, pp. 177
–182
. DOI: .15.
Standard ACI 440.1R-15
, “Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars
”. American Concrete Institute
, 2015
.
This content is only available via PDF.
© 2021 Author(s).
2021
Author(s)
You do not currently have access to this content.