In past several years, due to technology advancements, the costs of variable speed drives have come down sharply allowing the widespread applications of variable speed devices in building air-conditioning systems. This article presents the case study on application level of variable speed drives to the components of the air-conditioning system (VAV system) installed in Vivekanand Lecture Theatre Complex (VLTC) at MNIT Jaipur, India. After incorporating the variable speed drives to the air conditioning system, the proposed case energy performance index has been compared with the standard energy performance indexes of Energy Conservation Building Codes 2017(ECBC, ECBC+ and Super ECBC), developed by the ministry of power and Bureau of Energy Efficiency(BEE), India. The study of Hartman research paper on variable speed chiller plants has been used to learn existing algorithm for developing new operating strategies. Simulations are performed on EnergyPlusV8.8.0 (an energy analysis simulation program) for more than dozens of cases by making the variable a single and multiple combinations of HVAC equipment (AHU, Cooling Tower, Chiller, Pumps). The results show that the application of variable speed drives improved the performance of the air conditioning system substantially. At an average, the energy consumption of all variable chiller plant decreased by 40-45% compared to a constant speed chiller plant. All-variable speed chiller plant operating strategies have been developed based on the tailored specific performance characteristics of variable speed chillers and the variable flow characteristics of condenser pumps and cooling towers. The specific component-wise energy performance improvement after the incorporation of variable drives and ECBC compliance check for the proposed case has been presented in this paper.

3.
Hartman
,
T.
,
2001
.
All-variable speed centrifugal chiller plants
.
ASHRAE journal
,
43
(
9
), p.
43
.
5.
Hartman
,
T.
,
2002
.
All-variable speed centrifugal chiller plants: Can we make our plants more efficient
.
Automated Buildings
,
3
.
6.
Ben Erpelding
,
P.E.
,
C.E.M.
Ultra-Efficient
,
All-Variable Speed Chiller Plants A Green Building Imperative National Conference on Building Commissioning
: April 22 – 24,
2008
7.
Sahulhameedu
,
Smys
,
Joy
Chen
, and
Subarna
Shakya
, eds. “
P reface: International Conference on Inventive Research in Material Science and Technology (ICIRMCT 2018
).” In
AIP Conference Proceedings
, vol.
1966
, no.
1
, p.
010001
. AIP Publishing LLC,
2018
.
8.
Modelling of the coefficient of performance of an air-cooled screw chiller with variable speed condenser fans
.
Building and environment
,
41
(
4
), pp.
407
417
.
9.
Van Greunen
,
D.
,
Schutte
,
A.J.
and
Kleingeld
,
M.
,
2014
,
August. Energy efficiency through variable speed drive control on a cascading mine cooling system
. In
Industrial and Commercial Use of Energy (ICUE), 2014 International Conference on the
(pp.
1
6
).
IEEE
.
10.
Hydeman
,
M.
,
Webb
,
N.
,
Sreedharan
,
P.
and
Blanc
,
S.
,
2002
.
Development and testing of a reformulated regression -based electric chiller model
.
ASHRAE transactions
,
108
(
2
), pp.
1118
1127
.
11.
Smys
,
S.
,
Joy
Chen
, and
Subarna
Shakya
, eds. “
Preface: 2nd International Conferenceon Inventive Research in Material Science and Technology (ICIRMCT 2019
).” In
AIP Conference Proceedings
, vol.
2087
, no.
1
, p.
010001
. AIP Publishing LLC,
2019
.
12.
Yu
,
F.W.
and
Chan
,
K.T.
,
2008
.
Optimization of water-cooled chiller system with load-based speed control
.
Applied Energy
,
85
(
10
), pp.
931
950
.
13.
Hartman
,
T.
,
2014
.
All-variable speed centrifugal chiller plants
.
ASHRAE Journal
,
56
(
6
), pp.
68
79
.
This content is only available via PDF.
You do not currently have access to this content.