In this paper, energy modeling and management are conducted to reduce energy usage in the building. Several energy usage measures are proposed, which can be divided into active and passive design strategies. Inactive design strategy, more efficient devices are proposed to be installed, whereas, in passive design strategy, a specific insulator is suggested to be utilized. In this research, a calibration process is conducted to provide accurate results. It can be observed that approximately 36% of energy-saving equivalent to RM451,754 of electricity bill annually can be saved if all the measures are implemented. The payback period around 3.78 years can be obtained by considering the gross estimation of investment is RM 1,708,500.

1.
Zeeshan
S
, “
Case Study of Load Optimization of Energy Management in an Office Building
”.
International Journal of Advances in Engineering & Technology
,
6
(
6
),
2398
2407
,
2014
.
2.
Gupta
N
and
Shet
H.N
, “
Analysis of Measures to Improve Energy Performance of a Commercial Building by Energy Modeling
”,
Proceedings of the Online International Conference on Green Engineering and Technologies (IC-GET 2016), Coimbatore, India
, Nov.19,
2016
.
3.
Khamis
A
,
Alamshah
A
,
Ahmad
A
,
Rahman
A.A
and
Hairi
M.H
, “
Energy & Electricity Consumption Analysis of Malaysian Power Demand
4ᵗʰ International Power Engineering and Optimization Conference
,
Malaysia
,
23
24
,
2010
.
4.
Raftery
P
,
Keane
M
and
O’Donnell
J
, “
Calibrating whole building energy models: An evidence-based methodology
Energy and Buildings
,
43
(
9
),
2356
2364
,
2011
.
5.
Bakar
N.N.A.
 et al “
Identification building energy saving using energy efficiency index
”,
Proceedings of the IEEE International Conference on Power and Energy (PECon)
,
Sarawak, Malaysia
,
366
370
,
2014
.
6.
Ahmad
A.S
,
Hassa
M.Y
,
Abdullah
H
,
Rahman
H.A
,
Majid
M.S
and
Bandi
M
, “
Energy efficiency measurements in a Malaysian public university
Proceedings of the IEEE International Conference on Power and Energy (PECon), Kotakinabalu, Malaysia
,
2
5
,
2012
.
7.
Bukola
O.B
, “
Exergetic performance of a domestic refrigerator using R12 and its alternative refrigerants
”,
Journal of Engineering Science and Technology
,
5
(
4
),
435
446
,
2010
.
8.
Aravind
CV
,
Umashankar
Subramaniam
,
MD Shahrukh Adnan
Khan
,
Md. Ibrahim Ibne
Alam
, “
Options and Opportunities for Energy Management in Malaysian Grid Systems Putrajaya as a Case Study
Journal of Electronic Science and Technology
,
16
(
4
):
316
324
,
2018
.
This content is only available via PDF.