Photovoltaics (PV) power plants are very suitable in Indonesia which has an average intensity of solar radiation of 4kWh/m2 and has a practical system and installation. Therefore the number of solar power plants continues to increase, especially in the household scale. But people have a problem how to choose PV that are of good quality. This research was conducted to design a device that can be used to test the quality of a PV by comparing the output voltage and current produced by two PV simultaneously. The surface temperature of PV and light intensity is also measured to determine performance and calculate the efficiency of PV. Voltage, current, temperature, and light intensity are measured using sensors whose measurement data is processed by the microcontroller. In order for data to be analyzed and stored, the data is sent to LabVIEW. The result is that this tool successfully tested two PV with different brands at optimal conditions with the power produced by PV 1 was 51.06 Watts and PV was 45.13 Watts. For a full day performance monitoring, the efficiency of PV 1 was 15.8% and PV 2 was 14.6%.

1.
Sunarti
. et al 
Kajian Penyediaan dan Pemanfaatan Migas, Batubara, EBT dan Listrik
.
Jakarta
:
Pusat data dan Teknologi Informasi Kementrian ESDM
,
2017
.
2.
Madeti
,
S.R.
,
Singh
,
S.N.
, “Monitoring system for photovoltaic plants: A review”.
Renew. Sustain. Energy Rev
.
67
,
1180–1207
,
2017
.
3.
Moreno
,
Garcia
,
Isabel
M.
, “
Real-time monitoring system for a utility-scale photovoltaic power plant
”.
Sensors
16
(
6
),
770
,
2016
4.
W.
Herrmann
,
W.
Wiesner
and
W.
Vaassen
, “
Hot spot investigations on PV modules-new concepts for a test standard and consequences for module design with respect to bypass diodes
,”
Conference Record of the Twenty Sixth IEEE Photovoltaic Specialists Conference - 1997
,
Anaheim, CA, USA
,
1997
, pp.
1129
1132
.
5.
Takashima
,
T.
,
Yamaguchi
,
J.
,
Otani
,
K.
,
Oozeki
,
T.
,
Kato
,
K.
and
Ishida
,
M.
(
2009
)
Experimental Studies of Fault Location in PV Module Strings
.
Solar Energy Materials and Solar Cells
,
93
,
1079
1082
.
6.
James
Hare
,
Xiaofang
Shi
,
Shalabh
Gupta
,
Ali
Bazzi
,
Fault diagnostics in smart micro-grids: A survey
,
Renewable and Sustainable Energy Reviews
, Volume
60
,
2016
, Pages
1114
1124
.
7.
A.R.
Gxasheka
,
E.E.
van Dyk
,
E.L.
Meyer
,
Evaluation of performance parameters of PV modules deployed outdoors
,
Renewable Energy
, Volume
30
, Issue
4
,
2005
, Pages
611
620
.
8.
Grimaccia
,
F.
,
Aghaei
,
M.
,
Mussetta
,
M.
 et al 
Planning for PV plant performance monitoring by means of unmanned aerial systems (UAS
).
International Journal of Energy and Environmental Engineering
, March
2015
, Volume
6
, Issue
1
, pp
47
54
.
9.
T.
Nordmann
and
L.
Clavadetscher
, “
Understanding temperature effects on PV system performance
,”
3rd World Conference on Photovoltaic Energy Conversion, 2003
. Proceedings of,
Osaka
,
2003
, pp.
2243
2246
Vol.
3
.
This content is only available via PDF.
You do not currently have access to this content.