The Vortex tube is used for various applications like cooling of the equipments in CNC machines, refrigerators, cooling suits etc. This study converses the application of Taguchi method for establishing the influence of process parameters including type of material on the response, cold outlet temperature. Mild steel and the composite material - Epoxy polyester are the two materials used for the separate fabrication of Vortex tube. Experimental work has been carried out to analyze the performance of Vortex tube under the influence of five controllable input variables namely orifice diameter, nozzle diameter, hot tube length and diameter and inlet pressure of air. Cold temperature is considered as output response. Optimal cold outlet air temperature is found out by Taguchi’s parameter design. Analysis of Variance (ANOVA) established the stasistical significance of parameters on the response. Finally, the confirmation test is carried out to verify the results. The performance of Vortex tube fabricated with composite material is weighed against that made up of mild steel.
Skip Nav Destination
Article navigation
2 October 2019
RENEWABLE ENERGY SOURCES AND TECHNOLOGIES
14–15 March 2019
Tamil Nadu, India
Research Article|
October 02 2019
Experimental and comparative study on material effect of vortex tube on the cold outlet air temperature
G. Sankaraiah;
G. Sankaraiah
a)
1
Department of Mechanical Engineering, G Pulla Reddy Engineering College (Autonomous)
, Kurnool, Andhra Pradesh, INDIA
– 518007a)Corresponding author: [email protected]
Search for other works by this author on:
G. Suresh Kumar;
G. Suresh Kumar
b)
2
Department of Mechanical Engineering, G Pulla Reddy Engineering College (Autonomous)
, Kurnool, Andhra Pradesh, INDIA
– 518007
Search for other works by this author on:
V. Satish Kumar;
V. Satish Kumar
c)
3
Department of Mechanical Engineering, G Pulla Reddy Engineering College (Autonomous)
, Kurnool, Andhra Pradesh, INDIA
– 518007
Search for other works by this author on:
P. Venkateshwar Reddy
P. Venkateshwar Reddy
d)
4
Department of Mechanical Engineering, G Pulla Reddy Engineering College (Autonomous)
, Kurnool, Andhra Pradesh, INDIA
– 518007
Search for other works by this author on:
a)Corresponding author: [email protected]
AIP Conf. Proc. 2161, 020021 (2019)
Citation
G. Sankaraiah, G. Suresh Kumar, V. Satish Kumar, P. Venkateshwar Reddy; Experimental and comparative study on material effect of vortex tube on the cold outlet air temperature. AIP Conf. Proc. 2 October 2019; 2161 (1): 020021. https://doi.org/10.1063/1.5127612
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Production and characterization of corncob biochar for agricultural use
Praphatsorn Rattanaphaiboon, Nigran Homdoung, et al.