The cooling loads of air conditioning systems in public transportation have high energy consumtion to achieve human comfort standard. This study was focus on computational fluid dynamic approach analysis the Bladeless Air Curtain Unit (BACU) of the automatic door in light rapid transit (LRT) for saving cooing load. The installation the Bladeless ACU as a variable is obtained by vertical installation in a horizontal position on the top of the doorway. The inlet air sources of the Bladeless ACU on the same side of installation or opposite side installation are studied. The geometry model was a redesign from a commercial the Bladeless fan. The diagonal ratio was the ratio between the long of airfoil size to the wide of cross section airfoil; they are 2.5, 3.33, 5 and 10. The airflow speeds from the outlet of airfoil were varied; they are 5, 10, 15 and 20 m/s. The other parameter was the slit thickness varied 1, 1.5, 1.75, 2, 3 and 4 mm. The simulation result was showed that the discharge ratio decrese significantly while the airflow speed less than 10 m/s. The optimum velocity in varied gradient temperature between inside and outside carriage of LRT was found as corresponding to the highest performance of air curtain barried efficiency. The current study resulted that the performance of horizontal installation was reached 81%.

1.
Yuan
,
Feng-Dong
, and
Shi-Jun
You
. “
CFD simulation and optimization of the ventilation for subway side- platform
.”
Tunnelling and Underground Space Technology
22
.
4
(
2007
):
474
482
2.
Li
,
Jojo
SM
, and
W. K.
Chow
. “
Numerical studies on performance evaluation of tunnel ventilation safety systems
.”
Tunnelling and underground space technology
18
.
5
(
2003
):
435
452
.
3.
Shen
,
Chong
,
Xiaoliang
Shao
, and
Xianting
Li
. “
Potential of an air curtain system orientated to create a non- uniform indoor thermal environment and save energy
.”
Indoor and Built Environment
26
.
2
(
2017
):
152
165
.
4.
Trujillo
,
Francisco
Javier
, and
Q. Tuan
Pham
. “CFD modeling of simultaneous heat and mass transfer in beef chilling.”
Computational Fluid Dynamics in Food Processing
.
CRC Press
,
2007
.
216
242
.
5.
Qi
,
Dahai
, et al “
Parametric study of air curtain door aerodynamics performance based on experiments and numerical simulations
.”
Building and Environment
129
(
2018
):
65
73
.
6.
Cattarin
,
Giulio
, et al “
Outdoor test cells for building envelope experimental characterisation–A literature review
.”
Renewable and Sustainable Energy Reviews
54
(
2016
):
606
625
.
7.
Foster
,
A. M.
, et al “
Three-dimensional effects of an air curtain used to restrict cold room infiltration
.”
Applied Mathematical Modelling
31
.
6
(
2007
):
1109
1123
.
8.
Foster
,
A. M.
, et al “
Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration
.”
International journal of refrigeration
29
.
5
(
2006
):
692
699
.
9.
Ge
,
Y. T.
,
S. A.
Tassou
, and
A.
Hadawey
. “
Simulation of multi-deck medium temperature display cabinets with the integration of CFD and cooling coil models
.”
Applied Energy
87
.
10
(
2010
):
3178
3188
.
10.
Gonçalves
,
J. C.
, et al “
CFD modelling of aerodynamic sealing by vertical and horizontal air curtains
.”
Energy and Buildings
52
(
2012
):
153
160
.
11.
Marriott
,
Norman
G.
,
M. Wes
Schilling
, and
Robert B.
Gravani
. “
Pest control
.”
Principles of Food Sanitation.
Springer, Cham,
2018
.
243
266
.
12.
Hwang
,
Hyun-Min
, et al “
Occurrence of endocrine-disrupting chemicals in indoor dust
.”
The science of the Total Environment
404
.
1
(
2008
):
26
35
.
13.
Law,
S.
Edward
. “
Agricultural electrostatic spray application: a review of significant research and development during the 20th century
.”
Journal of Electrostatics
51
(
2001
):
25
42
.
14.
Chmielewski
,
Andrzej
G.
, and
Bumsoo
Han
. “Electron beam technology for environmental pollution control.”
Applications of Radiation Chemistry in the Fields of Industry, Biotechnology, and Environment
.
Springer, Cham
,
2017
.
37
66
.
15.
Brooks
,
Joe
E.
, and
William B.
Jackson
. “
A review of commensal rodents and their control
.”
CRC Critical Reviews in Environmental Control
3
.
1-4
(
1973
):
405
453
.
16.
D’Agaro
,
Paola
,
Giovanni
Cortella
, and
Giulio
Croce
. “
Two-and three-dimensional CFD applied to vertical display cabinets simulation
.”
International Journal of Refrigeration
29
.
2
(
2006
):
178
190
.
17.
Navaz
,
Homayun
K.
, et al “
Jet entrainment rate in air curtain of open refrigerated display cases
.”
International Journal of Refrigeration
28
.
2
(
2005
):
267
275
.
18.
Gaspar
,
Pedro
Dinis
,
LC Carrilho
Gonçalves
, and
R. A.
Pitarma
. “
Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions
.”
Applied Thermal Engineering
31
.
5
(
2011
):
961
969
.
19.
Chen
,
Yun-Guang
. “
Parametric evaluation of refrigerated air curtains for thermal insulation
.”
International Journal of Thermal Sciences
48
.
10
(
2009
):
1988
1996
.
20.
Costa
,
J. J.
,
L. A.
Oliveira
, and
M. C. G.
Silva
. “
Energy savings by aerodynamic sealing with a downward- blowing plane air curtain—A numerical approach
.”
Energy and Buildings
38
.
10
(
2006
):
1182
1193
.
21.
Juraeva
,
Makhsuda
,
Jun-ho
Lee
, and
Dong-Joo
Song
. “
A computational analysis of the train-wind to identify the best position for the air-curtain installation
.”
Journal of wind engineering and industrial aerodynamics
99
.
5
(
2011
):
554
559
.
22.
Smale
,
N. J.
,
J.
Moureh
, and
G.
Cortella
. “
A review of numerical models of airflow in refrigerated food applications
.”
International Journal of Refrigeration
29
.
6
(
2006
):
911
930
.
23.
Tsay
,
J.
, et al “
Evaluation Of A Pneumatic–Shielded Spraying System By Cfd Simulation
.”
Transactions of the ASAE
45
.
1
(
2002
):
47
This content is only available via PDF.
You do not currently have access to this content.