Demand for electricity is increasing rapidly, the consequence of this is a threat to the stability of the electrical system, one of which is the voltage stability. A flexible alternating current transmission system (FACTS) is a solid state electronic device is capable to regulate the transmission of electrical power be flexibly used to overcome these problems. This research will analyze the influence of Static Synchronous Compensator (STATCOM) placement, as one of the types of FACTS on the buses of the most critical voltage stability of the power system by using case Java-Bali 500 kV by means of simulation using PSAT software. Voltage stability observed with the help of the PV curve can indicate the value of each voltage at any operating conditions. Voltage value in which the system reaches the maximum loading parameter (MLP) is used to select the most critical bus or line as the location of STATCOM placement. Installation of SATCOM in case of Java-Bali 500 kV can increase MLP (λ) by 0,201 p.u. (5,22 %).
Skip Nav Destination
Article navigation
23 April 2019
THE 4TH INTERNATIONAL CONFERENCE ON INDUSTRIAL, MECHANICAL, ELECTRICAL, AND CHEMICAL ENGINEERING
9–11 October 2018
Surakarta, Indonesia
Research Article|
April 23 2019
Optimal placement of static synchronous compensator (STATCOM) to improve voltage stability based on sensitivity analysis in 500 kV Java-Bali electrical power system
Fasda Ilhaq Robbani;
Fasda Ilhaq Robbani
1Department of Electrical Engineering,
Sebelas Maret University
, Surakarta 57126, Indonesia
Search for other works by this author on:
Chico Hermanu B. A.;
Chico Hermanu B. A.
*
1Department of Electrical Engineering,
Sebelas Maret University
, Surakarta 57126, Indonesia
*Corresponding address: chico@ft.uns.ac.id
Search for other works by this author on:
Irwan Iftadi
Irwan Iftadi
1Department of Electrical Engineering,
Sebelas Maret University
, Surakarta 57126, Indonesia
Search for other works by this author on:
*Corresponding address: chico@ft.uns.ac.id
AIP Conf. Proc. 2097, 030014 (2019)
Citation
Fasda Ilhaq Robbani, Chico Hermanu B. A., Irwan Iftadi; Optimal placement of static synchronous compensator (STATCOM) to improve voltage stability based on sensitivity analysis in 500 kV Java-Bali electrical power system. AIP Conf. Proc. 23 April 2019; 2097 (1): 030014. https://doi.org/10.1063/1.5098189
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
43
Views
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Production and characterization of corncob biochar for agricultural use
Praphatsorn Rattanaphaiboon, Nigran Homdoung, et al.
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Related Content
Placement multi flexible alternating current transmission system (FACTS) : Static var compensator (SVC) and static synchronous compensator (STATCOM) for improving voltage stability of 500 KV Java-Bali electrical power system
AIP Conf. Proc. (April 2020)
Analysis of load flow and continuous power flow method in power system : A case study of 500 kV Java-Bali electrical power system
AIP Conf. Proc. (April 2020)
Cooperative control of D-statcoms to reduce voltage fluctuations
AIP Conf. Proc. (June 2023)
Drive and protection circuit for converter module of cascaded H-bridge STATCOM
AIP Conference Proceedings (April 2018)
Imperialist competitive algorithm for optimal design of on-grid hybrid green power system integrated with a static compensator for reactive power management
J. Renewable Sustainable Energy (February 2013)