The use of electrical energy on industrial loads often cause energy consumption problem which is not in accordance with the power needed by loads. The problem is caused by low loads power factor rating. Therefore, power factor correction is required by calculating installed loads capacity with the resulted power factor. Power factor correction can be done by using a magnetic energy recovery switch (MERS). MERS is a circuit located between sources and loads which control switching process on the capacitor. MERS is arranged of four MOSFET or IGBT as the switch. This research is done to know the characteristics of MERS and simulate it to correct the power factor of static loads. Static load is symbolized as RL. The specification of the load is obtained from research reference. This research implements MERS on a renewable energy source. The result of this research proves that MERS can correct static loads power factor from 0, 47 to 0, 98. The implementation on a renewable energy source showed if MERS is able to increase the value of static loads power factor.
Skip Nav Destination
Article navigation
23 April 2019
THE 4TH INTERNATIONAL CONFERENCE ON INDUSTRIAL, MECHANICAL, ELECTRICAL, AND CHEMICAL ENGINEERING
9–11 October 2018
Surakarta, Indonesia
Research Article|
April 23 2019
Design of variable reactive power compensator to improve power factor correction of a static load
Chico Hermanu B. A.;
Chico Hermanu B. A.
a)
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
2
National Center for Sustainable Transportation Technology
, Indonesia
a)Corresponding author: chico@ft.uns.ac.id
Search for other works by this author on:
Rio Yuan Pallafine;
Rio Yuan Pallafine
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
Search for other works by this author on:
Meiyanto Eko Sulistyo;
Meiyanto Eko Sulistyo
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
Search for other works by this author on:
Feri Andriyanto;
Feri Andriyanto
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
Search for other works by this author on:
Irwan Iftadi;
Irwan Iftadi
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
Search for other works by this author on:
Subuh Pramono
Subuh Pramono
1
Electrical Engineering Department, Faculty of Engineering, Universitas Sebelas Maret
, Surakarta 57126, Indonesia
Search for other works by this author on:
a)Corresponding author: chico@ft.uns.ac.id
AIP Conf. Proc. 2097, 030003 (2019)
Citation
Chico Hermanu B. A., Rio Yuan Pallafine, Meiyanto Eko Sulistyo, Feri Andriyanto, Irwan Iftadi, Subuh Pramono; Design of variable reactive power compensator to improve power factor correction of a static load. AIP Conf. Proc. 23 April 2019; 2097 (1): 030003. https://doi.org/10.1063/1.5098178
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Pay-Per-View Access
$40.00
33
Views
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Inkjet- and flextrail-printing of silicon polymer-based inks for local passivating contacts
Zohreh Kiaee, Andreas Lösel, et al.
Production and characterization of corncob biochar for agricultural use
Praphatsorn Rattanaphaiboon, Nigran Homdoung, et al.
Related Content
Design variables reactive power compensator using magnetic energy recovery switch (MERS) for induction motor
AIP Conf. Proc. (April 2020)