The aim of this experimental study was to assess the radiopacity of three endodontic sealers: a self-curing epoxy resin - AH Plus, a dual cure urethane dimethacrylate resin - RealSeal and a new dual cure endodontic hydroxyapatite based filling material developed in collaboration with “Raluca Ripan” Institute for Research in Chemistry from Cluj-Napoca. Material and methods: Five specimens, 10 mm diameter and 1 mm thickness, were digital x-rayed simultaneously with an aluminum step-wedge, varying from 1 to 12 mm thickness, according to ISO 6876:2012 standards. The radiopacity was determined by digital processing of the images, using specially designed software. Four different areas were selected for each specimen, according to quadrants of the sealer disks. Statistical analysis using ANOVA test was performed. Results: AH Plus sealer showed the highest radiopacity, the differences being statistically significant comparing to the others two tested sealers (p<0.05). Real Seal presented intermediate radiopacity values and the new experimental sealer radiopacity showed the lowest values (p>0.05). Conclusions: All tested materials were above the minimum radiopacity level recommended by the ISO 6876:2012. Acknowledgements: This work was funded by: the Romanian Ministry of Education and Research, National Project PN-II-PT-PCCA-2011-3.2-1275, no: 165/2012.
Skip Nav Destination
,
,
,
,
,
,
,
Article navigation
23 December 2015
10TH INTERNATIONAL CONFERENCE PROCESSES IN ISOTOPES AND MOLECULES (PIM 2015)
23–25 September 2015
Cluj-Napoca, Romania
Research Article|
December 23 2015
Radiopacity measurements of three endodontic sealers using digital x-rays Available to Purchase
R. Chisnoiu;
R. Chisnoiu
a)
1“Iuliu Haţieganu”
University of Medicine and Pharmacy
, Moţilor 33, 400001, Cluj-Napoca, Romania
Search for other works by this author on:
M. Moldovan;
M. Moldovan
b)
2“Raluca Ripan”
Chemistry Research Institute
, Fântânele 30, 400294, Cluj-Napoca, Romania
Search for other works by this author on:
O. Păstrav;
O. Păstrav
c)
1“Iuliu Haţieganu”
University of Medicine and Pharmacy
, Moţilor 33, 400001, Cluj-Napoca, Romania
Search for other works by this author on:
A. Delean;
A. Delean
d)
1“Iuliu Haţieganu”
University of Medicine and Pharmacy
, Moţilor 33, 400001, Cluj-Napoca, Romania
Search for other works by this author on:
D. Prodan;
D. Prodan
e)
2“Raluca Ripan”
Chemistry Research Institute
, Fântânele 30, 400294, Cluj-Napoca, Romania
Search for other works by this author on:
S. Boboia;
S. Boboia
f)
2“Raluca Ripan”
Chemistry Research Institute
, Fântânele 30, 400294, Cluj-Napoca, Romania
Search for other works by this author on:
V. Prejmerean;
V. Prejmerean
g)
3Faculty of Mathematics and Computer Science,
“Babeş Bolyai” University
, M. Kogălniceanu 1, 400084, Cluj-Napoca, Romania
Search for other works by this author on:
A. Chisnoiu
A. Chisnoiu
h)
1“Iuliu Haţieganu”
University of Medicine and Pharmacy
, Moţilor 33, 400001, Cluj-Napoca, Romania
Search for other works by this author on:
R. Chisnoiu
1,a)
M. Moldovan
2,b)
O. Păstrav
1,c)
A. Delean
1,d)
D. Prodan
2,e)
S. Boboia
2,f)
V. Prejmerean
3,g)
A. Chisnoiu
1,h)
1“Iuliu Haţieganu”
University of Medicine and Pharmacy
, Moţilor 33, 400001, Cluj-Napoca, Romania
2“Raluca Ripan”
Chemistry Research Institute
, Fântânele 30, 400294, Cluj-Napoca, Romania
3Faculty of Mathematics and Computer Science,
“Babeş Bolyai” University
, M. Kogălniceanu 1, 400084, Cluj-Napoca, Romania
AIP Conf. Proc. 1700, 060010 (2015)
Citation
R. Chisnoiu, M. Moldovan, O. Păstrav, A. Delean, D. Prodan, S. Boboia, V. Prejmerean, A. Chisnoiu; Radiopacity measurements of three endodontic sealers using digital x-rays. AIP Conf. Proc. 23 December 2015; 1700 (1): 060010. https://doi.org/10.1063/1.4938460
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
10
Views
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Classification data mining with Laplacian Smoothing on Naïve Bayes method
Ananda P. Noto, Dewi R. S. Saputro
Related Content
In vitro Study on Apical Sealing Ability of Nano‐Hydroxyapatite‐Filled Epoxy Resin Based Endodontic Sealer
AIP Conf. Proc. (March 2010)
Current obturation material removal in endodontic retreatment: A review articles
AIP Conf. Proc. (May 2024)
Evaluation of the bone repair in defects grafted with hydroxyapatite and collagen membrane combined with laser therapy in rats
J. Laser Appl. (November 2011)
Redesigning the continuous vacuum sealer packaging machine to improve the processing speed
AIP Conf. Proc. (January 2017)
Comparative in vitro study for orthodontic adhesives relatively to sorption and solubility
AIP Conf. Proc. (December 2015)