The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.
Skip Nav Destination
Article navigation
31 March 2015
41ST ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: Volume 34
20–25 July 2014
Boise, Idaho
Research Article|
March 31 2015
Observer POD for radiographic testing
Daniel Kanzler;
Daniel Kanzler
Federal Institute for Materials Testing and Research, Berlin,
Germany
Search for other works by this author on:
Uwe Ewert;
Uwe Ewert
Federal Institute for Materials Testing and Research, Berlin,
Germany
Search for other works by this author on:
Christina Müller;
Christina Müller
Federal Institute for Materials Testing and Research, Berlin,
Germany
Search for other works by this author on:
Jorma Pitkänen
Jorma Pitkänen
Posiva Oy, Eurajoki,
Finland
Search for other works by this author on:
AIP Conf. Proc. 1650, 562–570 (2015)
Citation
Daniel Kanzler, Uwe Ewert, Christina Müller, Jorma Pitkänen; Observer POD for radiographic testing. AIP Conf. Proc. 31 March 2015; 1650 (1): 562–570. https://doi.org/10.1063/1.4914654
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
Combining of different data pools for calculating a reliable POD for real defects
AIP Conference Proceedings (March 2015)
How much information do we need? A reflection of the correct use of real defects in POD-evaluations
AIP Conference Proceedings (February 2016)
Simulation supported POD for RT test case-concept and modeling
AIP Conference Proceedings (May 2012)
A benchmark concept for simulation in radiographic testing
AIP Conference Proceedings (February 2014)
Concepts for evaluation of image quality in digital radiology
AIP Conference Proceedings (May 2012)