X-ray laminography is a powerful technique for quality control of semiconductor components. Despite the advantages of nondestructive 3D imaging over 2D techniques based on sectioning, the acquisition time is still a major obstacle for practical use of the technique. In this paper, we consider the application of Discrete Tomography to laminography data, which can potentially reduce the scanning time while still maintaining a high reconstruction quality. By incorporating prior knowledge in the reconstruction algorithm about the materials present in the scanned object, far more accurate reconstructions can be obtained from the same measured data compared to classical reconstruction methods. We present a series of simulation experiments that illustrate the potential of the approach.
Skip Nav Destination
Article navigation
19 June 2014
STRESS INDUCED PHENOMENA AND RELIABILITY IN 3D MICROELECTRONICS
28–30 May 2012
Kyoto, Japan
Research Article|
June 19 2014
3D imaging of semiconductor components by discrete laminography Available to Purchase
K. J. Batenburg;
K. J. Batenburg
Centrum Wiskunde & Informatica, P.O. Box 94079, NL-1090 GB Amsterdam, The Netherlands and iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
Search for other works by this author on:
W. J. Palenstijn;
W. J. Palenstijn
iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
Search for other works by this author on:
J. Sijbers
J. Sijbers
iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
Search for other works by this author on:
K. J. Batenburg
Centrum Wiskunde & Informatica, P.O. Box 94079, NL-1090 GB Amsterdam, The Netherlands and iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
W. J. Palenstijn
iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
J. Sijbers
iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk,
Belgium
AIP Conf. Proc. 1601, 168–179 (2014)
Citation
K. J. Batenburg, W. J. Palenstijn, J. Sijbers; 3D imaging of semiconductor components by discrete laminography. AIP Conf. Proc. 19 June 2014; 1601 (1): 168–179. https://doi.org/10.1063/1.4881350
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Related Content
Phase-contrast and holographic computed laminography
Appl. Phys. Lett. (March 2009)
Development of x-ray laminography under an x-ray microscopic condition
Rev. Sci. Instrum. (July 2011)
High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography
Appl. Phys. Lett. (February 2005)
Three-dimensional imaging of dislocations by X-ray diffraction laminography
Appl. Phys. Lett. (December 2012)
On the implementation of computed laminography using synchrotron radiation
Rev. Sci. Instrum. (June 2011)