New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m2, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.
Skip Nav Destination
Article navigation
8 August 2013
LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013): Proceedings of the IV International Workshop in Low Radioactivity Techniques
10–12 April 2013
Laboratori del Gran Sasso, Assergi, Italy
Research Article|
August 08 2013
BiPo: A dedicated radiopurity detector for the SuperNEMO experiment
H. Gómez;
H. Gómez
Laboratoire de l'Accélérateur Linéaire. Centre Scientifique d'Orsay. Bâtiment 200 - BP 34. 91898 ORSAY Cedex,
France
Search for other works by this author on:
SuperNEMO Collaboration
SuperNEMO Collaboration
Laboratoire de l'Accélérateur Linéaire. Centre Scientifique d'Orsay. Bâtiment 200 - BP 34. 91898 ORSAY Cedex,
France
Search for other works by this author on:
AIP Conf. Proc. 1549, 94–97 (2013)
Citation
H. Gómez, SuperNEMO Collaboration; BiPo: A dedicated radiopurity detector for the SuperNEMO experiment. AIP Conf. Proc. 8 August 2013; 1549 (1): 94–97. https://doi.org/10.1063/1.4818084
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
14
Views
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Related Content
The BiPo detector for ultralow radioactivity measurements
AIP Conference Proceedings (March 2007)
Search for 0ν2β of 100Mo by NEMO-3 and status of SuperNEMO
AIP Conference Proceedings (July 2015)
Radon emanation chamber: High sensitivity measurements for the SuperNEMO experiment
AIP Conference Proceedings (August 2013)
UZ Dark Matter Searches at Canfranc
AIP Conference Proceedings (November 2006)
Radon and material radiopurity assessment for the NEXT double beta decay experiment
AIP Conf. Proc. (August 2015)