This paper presents an investigation of heat transfer correlation in a falling-film evaporator working with saline water at sub-atmospheric pressures. The experiments are conducted at different salinity levels ranging from 15000 to 90000 ppm, and the pressures were maintained between 0.92 to 2.81 kPa (corresponds to saturation temperatures of 5.9 – 23 0C). The effect of salinity, saturation pressures and chilled water temperatures on the heat transfer coefficient are accounted in the modified film evaporation correlations. The results are fitted to the Han & Fletcher's and Chun & Seban's falling-film correlations which are used in desalination industry. We modify the said correlations by adding salinity and saturation temperature corrections with respective indices to give a better agreement to our measured data.
Skip Nav Destination
Article navigation
29 June 2012
THE 4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011)
3–4 October 2011
Melaka, Malaysia
Research Article|
June 29 2012
An improved film evaporation correlation for saline water at sub-atmospheric pressures
Muhammad Wakil Shahzada;
Muhammad Wakil Shahzada
Department of Mechanical Engineering National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260,
Singapore
Search for other works by this author on:
Kim Choon Ng;
Kim Choon Ng
Department of Mechanical Engineering National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260,
Singapore
Search for other works by this author on:
Kyaw Thu;
Kyaw Thu
Department of Mechanical Engineering National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260,
Singapore
Search for other works by this author on:
Aung Myat;
Aung Myat
King Abdullah University of Science & Technology (KAUST),
Saudi Arabia
Search for other works by this author on:
Chun Won Gee
Chun Won Gee
Dept of Nuclear and Energy, Jeju National University, Jeju,
Republic of Korea
Search for other works by this author on:
AIP Conf. Proc. 1440, 1085–1091 (2012)
Citation
Muhammad Wakil Shahzada, Kim Choon Ng, Kyaw Thu, Aung Myat, Chun Won Gee; An improved film evaporation correlation for saline water at sub-atmospheric pressures. AIP Conf. Proc. 29 June 2012; 1440 (1): 1085–1091. https://doi.org/10.1063/1.4704324
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Animal intrusion detection system using Mask RCNN
C. Vijayakumaran, Dakshata, et al.
Related Content
Salinity reduction using capacitive deionization (CDI) reactor in batch system
AIP Conf. Proc. (May 2023)
Penetration height of weak axisymmetric fountain in homogeneous fluid under the combined temperature and salinity effect
AIP Advances (March 2022)
Characteristics of seawater ice slurry generation with salinity variation
AIP Conf. Proc. (January 2019)
Influence of water mass flow rate and water salinity on specific energy consumption and aquadest production using throttling process method
AIP Conf. Proc. (July 2020)
Effects of Salinity on Leaf Spectral Reflectance and Biochemical Parameters of Nitrogen Fixing Soybean Plants (Glycine max L.)
AIP Conference Proceedings (January 2010)