The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063‐41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.
Skip Nav Destination
Article navigation
28 May 2010
9TH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER AND NON‐CONTACT TECHNIQUES AND SHORT COURSE
22–25 June 2010
Ancona (Italy)
Research Article|
May 28 2010
Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations
Hans‐Jürgen von Martens
Hans‐Jürgen von Martens
Physikalisch‐Technische Bundesanstalt (retired), Abbestrasse 2‐12, 12587 Berlin, Germany
Search for other works by this author on:
AIP Conf. Proc. 1253, 423–445 (2010)
Citation
Hans‐Jürgen von Martens; Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations. AIP Conf. Proc. 28 May 2010; 1253 (1): 423–445. https://doi.org/10.1063/1.3455486
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Recognition of cat ras of face and body using convolutional neural networks
Akhmad Wahyu Aji, Esmeralda Contessa Djamal, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Related Content
Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry
Rev. Sci. Instrum. (December 2013)
International documentary standards and comparison of national physical measurement standards for the calibration of accelerometers
J Acoust Soc Am (October 2002)
Evaluation of measurement uncertainty in calibrations of laser vibrometers
AIP Conference Proceedings (May 2014)
Issues concerning international comparison of free‐field calibrations of acoustical standards
J Acoust Soc Am (October 2002)
Applicability of ISO standard methods to vibration measurements at high frequencies and high accelerations
AIP Conference Proceedings (June 2012)