Metallic magnetic calorimeters allow a high energy resolution even using absorbers with large heat capacities. For this reason, they are well suited for applications such as ionizing radiation metrology requiring gamma‐ray spectrometry with high detection efficiencies. We are developing detectors for gamma‐ray spectrometry with gold absorbers (1.0 mm diameter, 0.33 mm thickness) that have an intrinsic detection efficiency of about 60% at 100 keV. They have a theoretical energy resolution of 23 eV at 20 mK. The paramagnetic Au:Er sensor is coupled to a two‐stage SQUID setup via a meander shaped pickup coil made of a niobium thin‐film. For a temperature of 13 mK, one of our detectors showed an energy resolution of 58 eV at 81 keV. The baseline energy resolutions were 46 eV and 68 eV respectively at 13 mK and 20 mK, which is more than calculated; the measured signal sizes were smaller than expected. This problem can be overcome by sputter‐depositing the sensor (enriched in on the meander pickup coil; both the niobium and the Au:Er thin films are of high quality. The thermodynamic properties of a sputter‐deposited sensor were characterized below 100 mK for different bias currents up to 140 mA in the meander shaped pick‐up coil. We obtained a good agreement between the measured and calculated magnetizations, heat capacities and signal sizes. Hence, using these sensors for the next gamma‐ray magnetic calorimeter, we expect a significant improvement of the energy resolution in the near future.
Skip Nav Destination
Article navigation
16 December 2009
THE THIRTEENTH INTERNATIONAL WORKSHOP ON LOW TEMPERATURE DETECTORS—LTD13
20–24 July 2009
Stanford (California)
Research Article|
December 16 2009
Metallic magnetic calorimeters for γ‐ray spectrometry
M. Rodrigues;
M. Rodrigues
aCEA, LIST, Laboratoire National Henri Becquerel, F‐91191 Gif‐sur‐Yvette, France
Search for other works by this author on:
A. Pabinger;
A. Pabinger
bKirchhoff Institute for Physics, University of Heidelberg, INF 227, 69120 Heidelberg, Germany
Search for other works by this author on:
S. Lausberg;
S. Lausberg
bKirchhoff Institute for Physics, University of Heidelberg, INF 227, 69120 Heidelberg, Germany
Search for other works by this author on:
M. Loidl;
M. Loidl
aCEA, LIST, Laboratoire National Henri Becquerel, F‐91191 Gif‐sur‐Yvette, France
Search for other works by this author on:
B. Censier;
B. Censier
aCEA, LIST, Laboratoire National Henri Becquerel, F‐91191 Gif‐sur‐Yvette, France
Search for other works by this author on:
J. Bouchard;
J. Bouchard
aCEA, LIST, Laboratoire National Henri Becquerel, F‐91191 Gif‐sur‐Yvette, France
Search for other works by this author on:
L. Fleischmann;
L. Fleischmann
bKirchhoff Institute for Physics, University of Heidelberg, INF 227, 69120 Heidelberg, Germany
Search for other works by this author on:
A. Fleischmann;
A. Fleischmann
bKirchhoff Institute for Physics, University of Heidelberg, INF 227, 69120 Heidelberg, Germany
Search for other works by this author on:
C. Enss
C. Enss
bKirchhoff Institute for Physics, University of Heidelberg, INF 227, 69120 Heidelberg, Germany
Search for other works by this author on:
AIP Conf. Proc. 1185, 583–586 (2009)
Citation
M. Rodrigues, A. Pabinger, S. Lausberg, M. Loidl, B. Censier, J. Bouchard, L. Fleischmann, A. Fleischmann, C. Enss; Metallic magnetic calorimeters for γ‐ray spectrometry. AIP Conf. Proc. 16 December 2009; 1185 (1): 583–586. https://doi.org/10.1063/1.3292409
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
The effect of a balanced diet on improving the quality of life in malignant neoplasms
Yu. N. Melikova, A. S. Kuryndina, et al.
Animal intrusion detection system using Mask RCNN
C. Vijayakumaran, Dakshata, et al.