A regional Proton induced X‐ray Emission (PIXE) facility is newly developed using 3 Mev Proton beam from Variable Energy Cyclotron, Panjab University, Chandigarh (India). A new target chamber has been designed to cater for Proton Induced Gamma Emission (PIGE) and Rutherford Back Scattering (RBS) along with PIXE measurements. The HPGe x‐ray detector, the Ge (Li) gamma‐ray detector and a silicon surface barrier (SSB) detector can be mounted simultaneously in the chamber for this purpose. A remotely controlled stepper motor is provided to move the target wheel holding 12/24 samples at a time. This facility is now routinely used for the detection of trace elements in the aerosol, medical and forensic science samples. The paper presents the analysis of Aerosol samples collected from highly polluted steel city of Mandi Govindgarh in Punjab state and relatively clean city of Jammu in Jammu & Kashmir region. The results from the analysis of these samples show some basic differences in the trace element profile of the two cities. The paper also describes the trace element analysis of fly ash in the vicinity of Ropar Thermal Power plant in Punjab. The scope of this study was to determine the concentration and composition of atmospheric particulate matter (PM) in the vicinity of coal‐fired thermal power plants in India. The data taken for the Bio‐medical samples are also discussed.
Skip Nav Destination
Article navigation
10 March 2009
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: Twentieth International Conference
10–15 August 2008
Fort Worth (Texas)
Research Article|
March 10 2009
Regional PIXE facility at Chandigarh (India) and Trace Element Analysis of Aerosol and Bio‐medical Samples Available to Purchase
I. M. Govil
I. M. Govil
Department of Physics, Panjab University, Chandigarh 160014, India
Search for other works by this author on:
I. M. Govil
Department of Physics, Panjab University, Chandigarh 160014, India
AIP Conf. Proc. 1099, 269–273 (2009)
Citation
I. M. Govil; Regional PIXE facility at Chandigarh (India) and Trace Element Analysis of Aerosol and Bio‐medical Samples. AIP Conf. Proc. 10 March 2009; 1099 (1): 269–273. https://doi.org/10.1063/1.3120030
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
5
Views
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Design of a 100 MW solar power plant on wetland in Bangladesh
Apu Kowsar, Sumon Chandra Debnath, et al.
Related Content
Trace element analysis of soil samples using PIXE-PIGE technique: A review on Punjab Region
AIP Conf. Proc. (February 2024)
Implementing PIXE and PIGE at the Texas A&M University cyclotron institute
AIP Conf. Proc. (October 2019)
Power quality improvement by using real time values
AIP Conf. Proc. (October 2023)
Study of composition of seaweed of the genus Ulva and filter paper made with added algae by SEM-EDX, PIXE and PIGE
AIP Conf. Proc. (July 2023)
BSCAT-code for simulation and for analysis of the RBS/NRA spectra
AIP Conf. Proc. (February 1997)